EN
iAC88 - 8ch ADC + 8 ch DAC
Features:
•
8 analog outputs with 0 to 10V range and 100 levels;
•
50mA output current per channel;
•
8 analog inputs 0 to 10V volts or 4 to 20mA with 10bit
resolution;
•
MdiBus interface;
•
DIN Rail Distribution Board mounting.
Applications:
•
Control of devices with 0V to 10V analog interface;
•
Data acquisition from devices with 0-10V voltage or
4-20mA output.
Specifications:
Power supply voltage: 15VDC;
Consumption: 45mA nominal @ 15VDC;
Storage temperature: -10ºC a 60ºC;
Operating temperature: 10ºC a 50ºC;
Maximum humidity: 80% non-condensing;
Physical Specifications:
Dimensions: 157mm X 90mm X 70mm DIN rail mounting (9
modules);
Protection degree: IP20, for indoor use;
Self-extinguishing plastic box UL-94 V0;
Compatibility:
Compatibility with iThink module: V1.0 or higher.
Compatibility with Mordomus software: Mordomus iThink
V2017 or higher.
ATTENTION:
Never open the housing.
Never remove the circuit board from its housing.
Never crimp or cut cables while they are connected
to powered equipment.
The module is not provided with additional protection
against short circuit, therefore it is recommended to
use a power supply with the correct specifications.
Mordomus shall not be liable for any damages
resulting from the use of our equipment outside the
specifications and/or for a purpose other than that
intended.
When using a low cross section cable there might be
voltage drops that could force the module into under-
voltage protection mode.
Do not connect power supplies with an output current
greater than 4A.
The power supply shall never be connected to the
modules at the extremities of the bus as in
IAC88
Do not connect voltages greater than 10V to the
inputs of the iAC88.
Do not connect alternating current to the inputs of the
iAC88.
The power supply shall be connected to a central
module in order to distribute the power to the
remaining modules. For larger installations add as
many power supplies as required, always respecting
a uniform distribution. View
Overview:
MdiBus In connector
MdiBus Out connector
Power Supply iPSE154 (15V 4A)
Analog Outputs
Analog Inputs
Power supply connector 15VDC 2,1x5,5mm
Analog input mode selection
Addressing Button
Connections:
Cross Section of MDiBus + Power Supply conductors: CAT 6
UTP
Connection table - refer to
image
1, nr.
Nr
Function
Nr
1
Analog Output Ch1
14
2
GND
15
3
Analog Output Ch2
16
4
GND
17
5
Analog Output Ch3
18
6
GND
19
7
Analog Output Ch4
20
8
GND
21
9
Analog Output Ch5
22
10
GND
23
11
Analog Output Ch6
24
12
GND
25
13
Analog Output Ch7
26
figure
2.
MDiBus connection: To connect the module to the MDiBus a CAT
HW 1.0
6 UTP cable with RJ45 connectors according to EIA568A or
EIA568B standards must be used.
15VDC Power supply: It is recommended to use the iPSE154
power supply. The iAC88 module can source its power from other
nearby modules through the MDiBus cable.
Figure
3.
Enrollment:
To enroll the iAC88 module proceed as follows:
1.
Make sure that the iAC88 is powered by a suitable
power supply
.
2.
In the Mordomus software access the menu
Configurations
Modules/Addresses.
3.
On the iAC88, press and hold the addressing button
for at least 1sec. The green LED will blink slowly
until the addressing is complete.
4.
The iAC88 should be added automatically to the list
and the green LED should stop blinking.
Analog Input types: Each analog input can be defined to read
voltage (0-10V) or current (4 – 20mA). To select 4-20mA place
the jumper on the corresponding pins
jumper (factory default).
Analog Input settings: Delta expressed in percent, defines
the necessary input voltage variation to be considered a new
valid reading. This option is configurable in the Mordomus
Software.
Analog
Input
settings:
seconds/minutes, defines rate at which readings are taken.
This option is configurable in the Mordomus Software.
and
:
Power supply interruption: After an interruption of the power
Function
supply, each output will be reset to the state it was in at the time of
GND
interruption.
Analog Output Ch8
GND
Reset:
To perform a reset to the module, interrupt the 15VDC
Analog Input Ch1
power supply for 5 seconds.
Analog Input Ch2
Analog Input Ch3
LED codes:
Analog Input Ch4
GND
Green LED ON: Module powered and enrolled to software;
Analog Input Ch5
Red LED ON: Module powered and not enrolled to software;
Analog Input Ch6
Green and Red LEDs blinking simultaneously: Under-voltage
Analog Input Ch7
protection mode. Power supply voltage is to low;
Analog Input Ch8
Green LED blinking continuously: Module awaiting address
GND
definition;
Red LED flashing: Module sending/receiving data.
Note: The light of the green and red LEDs is visible through the
grid of the plastic enclosure.
RoHS
and connected to the MdiBus
http://mordomus.com/mordomus/docs/ithink/iAC88.pdf
and
access
the
sub-menu
. For 0-10V remove the
Refresh
rate
expressed
in
v.1916
This product complies with the Electromagnetic
Compatibility Directive 2014/30/EU.
This product conforms with the EU Directive 2011/65,
regarding the restriction of use of certain hazardous
substances in electric and electronic devices.
For EU countries only.
All old electrical and electronic devices must be
separated from normal household waste and disposed
of at designated facilities. For further information
contact your local authorities, waste disposal office or
the shop where you bought the device.
2/5