Features:
1 integrated temperature sensor;
MdiBus interface;
Mounting in wall box switches or other locations with
exposure to the temperatures to measure.
Applications:
Interior temperature reading.
Specifications:
Power supply voltage: 15VDC;
Consumption: 7mA nominal @ 15VDC;
Storage temperature: -10ºC a 60ºC;
Operating temperature: 10ºC a 50ºC;
Maximum humidity: 80% non-condensing;
Specifications for internal sensor:
Temperature range: 0ºC to 60ºC;
Resolution: 0,5ºC between 0ºC to 60ºC;
Physical Specifications:
Dimensions: 36mm x 36mm x 20mm;
Protection degree: IP00, for indoor use.
Compatibility:
Compatibility with iThink module: V1.0 or higher.
Compatibility with Mordomus software: Mordomus iThink
V2017 or higher.
ATTENTION:
Never crimp or cut cables while they are connected
to powered equipment.
The module is not provided with additional protection
against short circuit, therefore it is recommended to
use a power supply with the correct specifications.
Mordomus shall not be liable for any damages
resulting from the use of our equipment outside the
specifications and/or for a purpose other than that
intended.
Do not twist or bend the leads of the temperature
sensor excessively;
Due to the nature and reduced size of the module it is
not contained in any type of encapsulation and
should be treated accordingly. Prevent contact
between the module and any metallic or conductive
surface.
When using a low cross section cable there might be
voltage drops that could force the module into
undervoltage protection mode.
Overview:
iTM1
MdiBus and power supply connector
Status LEDs
Addressing button
Temperature sensor
iPSB connector
Connections:
Specification and cross section of conductors:
MdiBus + power supply conductors - CAT 6 UTP
Connection table MdiBus and power supply - refer to
nr.
and
:
Terminal of iPSB
Cable color
Terminal of
(Eg. Branch 1)
(UTP CAT6)
16
Green
MDiBus A OUT (Eg. Branch 1)
15
Green/White
MDiBus B OUT (Eg. Branch 1)
14
Blue
MDiBus A IN (Eg. Branch 1)
13
Blue/White
MDiBus B IN (Eg. Branch 1)
18
Orange
+ 15VDC
17
Orange/White
GND
18
Brown
+ 15VDC
17
Brown/White
GND
17
Shielding
GND
MDiBus and 15VDC power supply connection: The iTM1 should
be connected to the MdiBus and the power supply via the iPSB
module using UTP Cat6 cable.
The wire colors and connections in
the previous Table should be respected. The example specifies the
wiring from iTM1 to the branch 1 of the iPSB module.
Image
Connecting more than one iTM1 on the same iPSB branch:
The connection of multiple iTM1 modules in the same extension is
possible as long as the MDiBus passes through all the iTM1
modules and the last iTM1 module has the MDiBus return
connected to the MDiBus A IN and MDiBus B IN. See
image
HW 1.0
Enrollment:
To enroll the iTM1 module proceed as follows:
1.
Make sure that the iTM1 is powered by a suitable
power supply and connected to the MdiBus via an
iPSB module
and
2.
In the Mordomus software access the menu
Configurations and access the sub-menu Modules/
Addresses.
3.
On the iTM1, press and hold the addressing button
for at least 1sec. The green LED
slowly until the addressing is complete.
4.
The iTM1 should be added automatically to the list
image
1,
and the green LED
should stop blinking.
The frequency of the temperature updates (refresh rate) can
be defined in the Mordomus Software by selecting the desired
iTM1
input in Configurations, Modules/Addresses. Possible values
3
are: 1, 3, 5, 10, 30 seconds and 1, 3, 5, 10, 30 minutes. The default
is 10 seconds.
2
Reset:
To perform a reset to the module, interrupt the 15VDC
3
power supply for 5 seconds.
2
LED codes
:
4
Green LED ON: Module powered and enrolled to Mordomus
software;
1
Red LED ON: Module powered and not enrolled to Mordomus
Software;
4
Green and Red LEDs blinking simultaneously: Module in
undervoltage protection mode. Power supply voltage is too
1
Green LED blinking continuously: Module awaiting address
definition;
1
Red LED blinking: Module sending/receiving data.
This product complies with the Electromagnetic
Compatibility Directive 2014/30/EU.
1.
This product conforms with the EU Directive 2011/65,
RoHS
regarding the restriction of use of certain hazardous
substances in electric and electronic devices.
For EU countries only.
All old electrical and electronic devices must be
separated from normal household waste and disposed
2.
of at designated facilities. For further information
contact your local authorities, waste disposal office or
the shop where you bought the device.
v.2105
http://mordomus.com/mordomus/docs/ithink/iTM1.pdf
http://mordomus.com/mordomus/docs/ithink/iPSB.pdf
.
will blink