PULSES OUTPUT
The pulses output of the SAG-105WR is an optocoupled open
collector output. Relationship between wind speed and frequency:
V (km/h) = 0.92 * frecuencia (Hz) + 3
An external power supply or the internal one can be used.
USING AN EXTERNAL POWER SUPPLY
Positive external power supply is connected to terminal 2. Pulses
output signal is supplied between terminal 3 and negative of power
supply.
Features
Maximum current
Maximum voltage
Minimum impedance at 24 Vdc
1
2
+
3
PULSES
4
OUTPUT
RELAYS
The relays of the SAG-105WR are in the 5-8 terminals of the
connector of the pulses output. Relay number 1 is asociated with
the pre-alarm, it will be activated intermently when the pre-alarm is
activated. Relay number 2, is activated continuosly when the alarm
is activated.
Electrónica al servicio
de la industria
SAG-105WR
PULSES OUTPUT AND RELAYS ANNEX
25 mA
24 V
1000 Ω
+
EXTERNAL POWER
SUPPLY
IED Electronics Solutions S.L.
Pol. Plazaola E 6, 31195 Aizoáin. Navarra (Spain)
www.iedelectronics.com
info@iedelectronics.com
USING THE INTERNAL POWER SUPPLY
If an external power supply is not available, the internal one can be
used(+12 Vdc). The output signal is supplied between the terminal
3 (+) and 4 (-). This is the recommended connection to connect the
WM44-P.
Features
Maximum current
Maximum output voltage
Minimum impedance
1
2
3
4
Features
Relay quantity
Contact type
Maximum voltage
Maximum current
25 mA
12 V
500 Ω
+
PULSE S
OUTPU T
-
2
Normally open, dry contact
250 Vac
3 A