7. During use the lid handle will change colour and show the hot hazard symbol when hot
steriliser to cool down for at least 10 minutes between cycles. As a safety mechanism the unit will not allow you
to switch it on again until it is ready for use.
WARNING: Beware of hot steam escaping from the steam vent during use.
8. When your steriliser has cooled, switch off, unplug at the mains and disconnect the lead (I).
9. Remove the bottle holder, pour away any remaining water (J) and wipe the inside of the steriliser dry (K).
STERILISING BOTTLES (See fig. 2)
1. Wash your bottles and accessories thoroughly in warm soapy water before sterilisation.
2. Remove all items from the steriliser.
3. Fill the measuring cup up to the water level mark (120 ml / 4 fl. oz.) with fresh cold water (L) and pour into the base
of the steriliser (M).
4. Arrange your bottles upside down on the Accessory tray 1 of your bottle holder. The Accessory tray 2 then slides
down over the central rod to hold the bottles in place (N).
5. Insert the bottle holder into the steriliser, arrange your bottle accessories on the Accessory tray 2 (O) and bottle
tongs into central rod.
6. Replace the lid (P) and lock closed using the side handles (Q).
7. Plug the power cord into the rear of the steriliser before plugging it into your wall socket (R).
PLEASE ENSURE THAT THE CORD AND UNIT ARE OUT OF REACH OF CHILDREN!
8. Press the 'power on' switch to start the sterilisation cycle (S). The unit will switch itself off after completing its cycle -
approximately 6 minutes. (6 minutes is the sterilisation time for a full unit containing 8 bottles. For lighter loads the
sterilisation time will increase).
9. During use the lid handle will change colour and display
steriliser to cool down for at least 10 minutes between cycles. As a safety mechanism the unit will not allow you
to switch it on again until it is ready for use.
WARNING: Take care when opening the lid as the handle will be hot. Beware of hot steam escaping from the steam
vent during use.
10. When your steriliser has cooled, switch off and unplug at the mains and disconnect the lead (U).
REMOVING STERILISED ITEMS
11. Always allow at least 10 mins cooling time before removing sterilised items.
12. Use caution when removing the lid as steam escapes.
13. When removing sterilised items from the steriliser use caution - the steriliser will still be hot.
14. Always wash your hands before handling sterilised items and make all possible efforts to avoid contamination.
15. To keep small components such as teats as sterile as possible, we would suggest using the tongs. The tongs
themselves may be sterilised in the unit and should be placed at the top for easy access after sterilisation.
16. After each use pour away any excess water (V) then rinse and wipe dry the steriliser (W).
CLEANING YOUR STERILISER
IT IS VERY IMPORTANT THAT YOU CLEAN YOUR STERILISER AT LEAST ONCE A WEEK. REGULAR CLEANING
WILL MAINTAIN THE PRODUCTS PERFORMANCE. FAILURE TO OBSERVE THE CLEANING INSTRUCTIONS
OR MISUSE OF THE PRODUCT WILL INVALIDATE YOUR GUARANTEE.
Your measuring cup has a filter which will remove some but not all mineral deposits present in our water supply. Without
regular cleaning these will eventually build up on the heating element. Sterilising using preboiled water should reduce
the quantity of minerals present further.
WARNING: Before cleaning ensure you have disconnected your steriliser from the mains. Allow 20 - 30 minutes
for the unit to cool following your last use. Take care when removing lid.
1. Clean the exterior of the unit with a soft damp cloth. Do not immerse in water!
2. Remove the bottle holder from the steriliser and wash it separately in warm soapy water.
3. To remove any lime scale deposits use one of the methods below.
CITRIC ACID (available at most chemists)
1. Mix 1 sachet of Citric Acid with water as directed on the manufacturers instructions and pour into the unit.
Do not put the lid on!
2. Switch on the unit for 1-2 minutes.
3. Switch off at the mains then unplug and disconnect. Allow the unit to stand for 30 minutes.
4. Drain the steriliser and then rinse fully.
4
All manuals and user guides at all-guides.com
(H). Always allow your
symbol to indicate unit is hot (T). Always allow your
5. Run a full empty cycle with the LID ON using 120 ml / 4 fl. oz. of water measured with your measuring cup.
6. Allow your steriliser to cool and wipe dry.
WHITE HOUSEHOLD VINEGAR
1. Fill the measuring cup with half water and half white household vinegar and pour into the steriliser.
2. Replace the lid and switch on the unit for one complete cycle. Ensure you allow adequate ventilation
for the strong vinegar odour!
3. Allow the unit to cool for at least 10 minutes.
4. Drain the steriliser and rinse fully.
5. Run a full empty cycle with the LID ON using 120 ml / 4 fl. oz. of water measured with your measuring cup.
6. Allow your steriliser to cool. Pour out any excess water and wipe dry.
TROUBLE SHOOTING GUIDE
Steriliser will not work
Steriliser takes a long time to complete its cycle
Steriliser is switching off too soon
How long will the bottles stay sterile
after sterilisation?
Water will not pass through
the measuring cup filter

TECHNICAL DATA

~
Voltage: 220V-240V
50Hz Rating: 915 - 1089W
VEUILLEZ CONSERVER CE MODE D'EMPLOI POUR POUVOIR
VOUS Y RÉFÉRER ULTÉRIEUREMENT
IMPORTANT ! Veuillez lire l'intégralité de ce mode d'emploi avant d'utiliser votre stérilisateur.
AVERTISSEMENT ! RISQUE DE STRANGULATION ! Ne pas laisser l'appareil à la portée des enfants. Ne pas utiliser
l'appareil avec des rallonges électriques.
CONTENU
a Couvercle transparent
b Porte-biberons
c Plateau à accessoires 1
d Plateau à accessoires 2
e Poignées latérales
f Gobelet mesureur d'eau avec filtre
g Pince pour biberons
VITESSE
Le stérilisateur électrique rapide de Munchkin est un stérilisateur rapide et efficace réalisant un cycle complet en à peine
6 minutes. Il détruit les bactéries nocives en entourant vos biberons et accessoires de vapeur. Votre stérilisateur peut
contenir un maximum de 9 biberons classiques ou 6 biberons à ouverture large ainsi que leurs accessoires.
• Check that the mains lead is connected and switched on.
• Remove all remaining water after each cycle. Any excess
water (beyond 120 ml / 4 fl. oz.) will increase cycle time.
• Ensure that you use the measuring cup to measure exactly
120 ml / 4 fl. oz. of water (any excess water will increase the cycle time).
• If your steriliser is partially loaded (e.g. only 2 bottles) the cycle
time will increase slightly.
• Not enough water is being used. Ensure you use the measuring
cup to measure exactly 120 ml / 4 fl. oz. of water.
• Ensure the steriliser is empty and the water is poured directly
onto the element (i.e. not splashed around the surrounding plastic).
• Providing the lid is not opened, the contents of the steriliser will
remain sterile for up to 6 hours.
• Run the mesh under water to break the surface tension
before refilling.