Velleman HAA85 Manual Del Usuario página 3

Teclado de seguridad multifunción
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

HAA85 – MULTIPURPOSE SECURITY KEYPAD
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm
the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized
company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for buying the HAA85! Please read the manual thoroughly before bringing this device into service. If the
device was damaged in transit, don't install or use it and contact your dealer.
The HAA85 is a self-contained dual-output security keypad, designed for electric door strike and security control
applications. It employs EEPROM, the stored data is non-volatile in case of power failure. Over 100 million
combinations are possible for the user codes (code 1 & code 2) and the master code (it also acts as the super user
code). The user code 1 can be altered to act as a duress code to activate the duress output for reporting duress to an
alarm system or to a telephone dialler. The keypad can be configured to have different operation combinations by
using the two user code outputs, such as utilizing code 1 for door strike and code 2 for alarm ON-OFF control; or
making code 1 for alarm ON-OFF control and code 2 for reporting panic event to an alarm system.
2. Connections
RED
AMBER
GREEN
1
2
3
4
5
6
7
8
9
*
0
#
* 12V DC POWER:
* OUTPUT RELAY 1: 2 Amp dry relay contacts, with Normally Open (N.O.) and Normally Closed (N.C.) terminals.
This relay is prepared for door strike or alarm ON-OFF control connection. Use the N.O. contact for door
strike connection. If for alarm ON-OFF control, connect the appropriate pair of these terminals (N.C. or
N.O.) to the remote ARM/DISARM terminals on your alarm system; consult the manual for your system.
N.O. or N.C. loop is possible. Relay contact is programmable for momentary or start/stop operation.
HAA85
Connect to 12VDC power supply. The (-) supply is the grounding point of the keypad.
3
VELLEMAN

Publicidad

Tabla de contenido
loading

Tabla de contenido