iNSTallaTiON
Service information
1.
5
4.
4
1 Flow limiter
2 O-ring
3 Cold water pipe bend with recess for spring clip
4 Spring clip
5 Heater
f Remove the cold water pipe bend and the O-ring.
f
f Insert the flow limiter (part of the appliance standard deliv-
f
ery) in the cold water inlet of the heater. Note the orientation.
f Fit the cold water pipe bend with the O-ring.
f
Material losses
!
The O-ring must be fitted to prevent the appliance from
leaking.
f As part of installation, check that the O-ring is in
f
place.
f Secure the cold water pipe bend with the spring clip.
f
Material losses
!
Ensure that the spring clip is located behind the recess
in the pipe bend and that it is securely holding the pipe
bend in place.
f Fit the function module on the appliance back panel in re-
f
verse order until it clicks into place.
f Secure the function module with the screw.
f
Installing the appliance
1
1 Grommets
2 Flat gasket
3 Strainer with sealed edge
12
| DCE-S Plus
2.
3.
1
2 3
2
3
f Mark out the 2 drilling positions in the upper section of the
f
appliance back panel with reference to the appliance back
panel.
f Fit the grommets in the appliance back panel from the front.
f
f Drill the holes and secure the appliance using suitable fixing
f
materials (screws and rawl plugs are not part of the standard
delivery): Countersunk screw, Ø 4.5 mm, max. diameter of
screw-head 9 mm.
Note
f Install the appliance flush to the wall. If necessary,
f
additionally secure the appliance at the 2 lower
attachment points. To do this, push/break out the
lower slots (175 mm apart) in the appliance back
panel (for positions, see chapter "Specification / Di-
mensions and connections").
f Remove the transport protection plugs from the water con-
f
nection pipes.
f Secure the DHW connection pipe with a flat gasket and the
f
cold water inlet line with the sealed-edge strainer (from the
accessories) to the twin connectors.
12.6 Operation with preheated water
You can limit the maximum inlet temperature by installing a cen-
tral thermostatic valve.
13. Service information
Connection overview / component overview
1
2
1 Flow meter
2 High limit safety cut-out, automatic reset
3 NTC sensor
4 Pin strips for connected load and anti-scalding protection
5 Programming unit plug-in position
6 Diagnostic traffic lights
3
4
5
6