Descargar Imprimir esta página

Olimpia splendid SITALI SFE 100 Manual De Instrucciones página 7

Ocultar thumbs Ver también para SITALI SFE 100:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Trickle speed can be set to off (fig. 15).
To deactivate the humidistat function, turn the trimmer HY completely clockwise.
Automatic humidistat operation: when the percentage of Relative Humidity exceeds
the settable threshold, fan speed automatically increases to "comfort boost" speed,
which is intermediate between the selected trickle speed and the boost speed. When
the percentage of Relative Humidity goes below the threshold, the fan continues
to function at "comfort boost" speed for a factory set period of time then returns to
selected trickle speed.
Operation with external switch (fig. 13): when the external switch is turned on, the fan
is boosted. After the external switch is turned off, the fan continues to run at boost
speed for a settable period of time, then it returns to selected trickle speed (or to
"comfort boost" speed in case automatic humidistat operation is on). The front cover
LED indicates when the external switch is on.
The over-run timer function is activated only if the external switch has been on for at
least 60 seconds.
INSTALLATION TYPE SETTING
Installation type can be selected using JUMPER 1 between the following options:
through wall or ducted (fig. 15).
TRICKLE SPEED SETTING
Trickle speed can be selected using JUMPER (fig. 15).
STANDARD CONFORMITY
2014/35/EU Low Voltage Directive (LVD)
2014/30/EU Electromagnetic Compatibility (EMC), in conformity with the following
standards:
Electrical Safety: EN60335-1(2012)+A11+A13; EN 60335-2-80(2003)+A1+A2
Electromagnetic Compatibility: EN 55014-1(2017); EN 55014-2(2015); EN 61000-3-
2(2014); EN 61000-3-3(2013).