SET-UP

Location of Air Compressor

Operate air compressor in a clean, dry and well ventilated area. The air filter
must be kept clear of obstructions which could reduce air flow to the compressor.
The air compressor should be located at least 12" away from walls or other
obstructions that could interfere with the flow of air.
1. Remove the air compressor from the carton and
place it on its side.
2. Install the 4 rubber feet with the screws
included in the accessory kit as shown.
3. Close the tank drain valve.
4. Remove 2 head screws and install handle
with hardware included in accessory kit.
5. Turn on/auto/off lever on the pressure switch
to the "OFF" position.
6. Attach air hose to the compressor manifold.
7. Plug the power cord into a grounded outlet
or approved extension cord. (See Grounding
Instruction section) Turn the on/auto/off lever
on the pressure switch to the "ON" position.

Extension Cords

To avoid voltage drop and power loss to motor, use additional hose instead
of an extension cord. If an extension cord must be used, use only a 3-wire
extension cord equipped with a 3-blade grounding plug and a 3-slot receptacle
that will accept the plug on the compressor. Be sure to use an extension cord
heavy enough to carry the current your product will draw. An undersized cord
will cause a drop in line voltage resulting in loss of power and overheating.
Make sure the extension cord is in good condition.
NOTE: Wire size increases as gauge number decreases.
CORD LENGTH 25 FEET 50 FEET 100 FEET 150 FEET
MINIMUM GAUGE FOR EXTENSION CORDS
GAUGE
12
12
tank drain
valve
attach feet
(2) each side
attach air hose
10
8
3