General Info; Installation And Configuration - Perenio PELUV01 Guia De Inicio Rapido

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9

GENERAL INFO

Specification
Recommended
Exposure Time
1
2
Casing
Scope of Supply
Warranty

INSTALLATION AND CONFIGURATION

1. Unpack the UV Lamp and accessories and mount brackets ❺ in the desired UV Lamp installation
area using screws ❹ (See Figure ❻).
2. Fix the lamp bracket ❷ into mounting brackets (See Figure ❼).
3. Insert the UV tube ❶ into the lamp bracket (See Figure ❽).
4. Connect the power cord ❸ to the UV Lamp (Don't plug it into the source of power).
5. Select one of two options to operate the UV Lamp.
Option 1 (See ❾a). Remote operation via a Perenio® Power Link device.
a. Activate the Power Link device in the Perenio Smart or Perenio Lite mobile application as described
in a corresponding user manual (Power Link device is sold separately);
b. Power off the activated Power Link device (Don't unplug it from the source of power);
c. Connect the UV Lamp to the Power Link device using the power cord;
d. Use functionality of the Power Link device to switch on or off the UV Lamp remotely from the mobile
app (e.g. timers, scenarios, power on/off function).
NOTE that if used with the Power Link device, the UV Lamp may additionally be managed from Google
Home, Yandex Smart Home (Alice), Amazon Alexa or Apple Siri apps. Follow instructions specified in
corresponding guides of Apple, Google or Yandex applications or refer to the FAQ Section of
perenio.com web-site.
Option 2 (See ❾b). Manual operation.
a. Plug the UV Lamp into the mains socket to power it on;
b. Unplug the UV Lamp from the mains socket to power it off.
ATTENTION! ALWAYS PLUG AND UNPLUG THE DEVICE WITH DRY HANDS!
SAFETY OPERATION RULES
The device shall be used as described in this QSG and a complete manual only. Any other use not
specified therein may cause fire, electric shock and other hazards, as well as injury to persons. The
most effective way to use the device is in rooms with no air circulation at an ambient temperature of
+25°C. The device must be installed a minimum of 1.8 m away from plastic and rubber materials such
as flexible duct, wire insulation, filters, etc., because the UVC light may damage them. Otherwise,
such materials must be protected from direct UVC light using aluminum foil tape. It is forbidden to
operate the device, if any part of the device is damaged or cracked. The device shall not be installed
rooftop or outdoors, or near water including humidifiers. The device shall be kept away from direct
sunlight, moisture and vibration. It is not allowed to use the device with a damaged power cord, or
put the power cord near radiators, stoves or heaters. It is recommended to replace the UV tube once
a year notwithstanding its good condition. Prior to powering on the device, the UV tube shall be cleaned
with a cotton cloth to remove dirt and fingerprints, otherwise it may shorten the UV tube lifespan. It
is not allowed to use any detergents to clean any part of the device. If the UV tube is broken, all
particles shall be swept into a plastic bag, sealed and disposed of properly, because the device contains
mercury. Do not use a vacuum cleaner to pick up the waste and glass particles. Contact your local
waste collection agency for proper disposal procedures. Keep children away from the device, because
it may emit a light attractive to them. Serious injury and electrocution might be possible. This device
is intended to be operated by adults only.
WARNINGS AND PRECAUTIONS
UVC LIGHT IS HARMFUL TO EYES! DON'T LOOK AT THE UV TUBE DURING OPERATION!
The UV Lamp is not a medical device. People, pets and plants must not present in the room under
UVC exposure. Read and understand all instructions and precautions in this QSG and a complete
manual. Failure to follow manufacturer instructions may result in fire, electric shock and other hazards,
as well as lead to serious injury to persons. Warnings, precautions and instructions herein cannot
cover all possible hazardous situations that may occur. User must show common sense when using
the device. It is forbidden to look into operating UV tube, because any UVC light exposure
causes significant eye damage, as well as may cause skin damage. So, whenever the device
is powered on, wear UV eye and skin protection. To prevent exposure to UV light, disconnect the
device from the source of power as soon as disinfection process is completed. Ingestion or contact
with mercury or its vapor is hazardous to health. So, if the device is broken, avoid contact with
mercury. It is forbidden to touch the UV Lamp with wet hands. The device is not intended to be used
for removal of active mold growth. The UVC light exposure to existing mold growth can cause
respiratory irritation and allergic symptoms. The UVC light exposure may also cause fabric
discoloration, as well as damage to plastic and rubber materials. The UVC light of the device does not
provide a tanning effect, while its exposure to uncovered skin areas for more than 2-3 minutes will
causes burns.
TROUBLESHOOTING
1. The UV Lamp does not power on: The UV tube is not in close contact with the lamp bracket.
Reassemble the UV Lamp device.
2. The UV tube does not work: The UV tube is damaged, or the end of life of the UV tube occurred.
Replace the UV tube.
1
Please ventilate the room for at least 30 minutes after each UV lamp exposure. During UV Lamp exposure, all doors
and windows in this room must be closed. Exposure time should be increased, if the room temperature is below
+20°C or above +40°C, or when the device is operated in wet environment like bathroom. A single UVC light
exposure period shall not exceed 90 minutes. It is recommended to use the UV Lamp once or twice a week for about
30 minutes each time.
2
This device is for indoor installation only. Operating conditions: 0°C to +40°C, up to 75% RH.
3
Manufactured by Perenio IoT spol s r.o. (Na Dlouhem 79, Ricany - Jazlovice 251 01, Czech Republic). Made in
China. See operating conditions and date of manufacture on the individual packaging. All information contained
herein is subject to amendments without prior notification of the User. For current information and details on the
device description and specification, connection process, certificates, warranty and quality issues, as well as the
Perenio Smart/Perenio Lite app functionality, see relevant Installation and Operation Manuals available for
downloading at perenio.com/documents. All trademarks and names herein are the property of their respective owners.
4
40V to 100V (Output), 100mA to 250mA, 220VAC to 240VAC (Input), 50/60Hz,
20W (Power), electrical ballast, UVC light, 260-275nm (Wavelength), 78μw/cm
(Intensity), up to 30m
610 mm x 30 mm x 50 mm (Lamp bracket), Ø26 mm x 588 mm (UV tube)
15 minutes (for area of up to 10 m
45 minutes (for area of up to 30 m
IP20 Protection Class, base type G13, bulb type T8, pig iron (Lamp bracket),
quartz glass (UV tube)
PELUV01 UV Lamp (UV tube ❶ and lamp bracket ❷), power cord ❸, screws
and dowels ❹, mounting brackets ❺, Quick Start Guide, Warranty Card
2 years (UV tube lifespan: 6,000 hours)
2
(Coverage area), 240° (Coverage angle). Dimensions:
2
), 30 minutes (for area of up to 20 m
2
)
3
Doc Date: 12/11/2020
©Perenio IoT spol s r.o.
2
2
),
Version: 2.0.0
All Rights Reserved

Publicidad

Tabla de contenido
loading

Tabla de contenido