7. MECHANICAL SAFETY (see fig.1)
The hazardous points on the IMER mixer are protected by means
of suitable safety devices, which must remain fitted at all times and
kept in perfect condition. For example, this includes the electric
motor cooling fan guard and the hopper grid (ref. 10) to prevent
contact with the auger.
Also, release of the mixing chamber, shuts down all rotary parts
of the machine immediately thanks to a specific safety device.
8. TRANSPORT (see fig.2 and fig.3)
- CAUTION! Before moving the mixer, always detach
the power plug.
Before moving the mixer, disconnect the water supply hose.
Only a minimal amount of the material should be in the hopper
when handling.
Lift the mixer by means of the relative handles (fig.2) and
push in the required direction.
-CAUTION! Before lifting the mixer, always check that all ma-
chine components are correctly secured and fitted in place
and no objects have been left on the surface
- CAUTION! Lift with care to avoid hazardous oscillations
- CAUTION! Never use points other than as specified in figure
3 to lift the machine
To lift the machine, use the four specific attachment rings (fig.3).
IMER INTERNATIONAL S.p.A.
SPIN 15
9. INSTALLATION
Position the mixer on a flat surface in a suitably ventilated envi-
ronment where it does not constitute an obstruction either during
use or cleaning at the end of the work shift.
- Position the mixer on a flat surface or slightly inclined towards
the material outlet.
10. CONNECTIONS
10.1 ELECTRICAL CONNECTION (see fig.5)
and electrical connection (socket, fuses, cable) correspond
to specifications in table 1.
The electrical power socket must be fitted with protection against
current overload (e.g. by means of fuses or a thermal magnetic
cut-out) and against dispersion current to earth (e.g. with a dif-
ferential circuit breaker). The electric cable wire size must take
into account the operating currents and length of the line to avoid
excessive voltage drops.
Avoid use of extension leads wound on drums. The power cable
must be suitable for frequent movements and with an abrasion
resistant sheath
(e.g. type H07RN-F).
Before connecting the mixer to the electrical mains, ensure that all
safety devices are fitted and are in perfect condition, and check in
particular that the hopper grid is secured in place, that the exten-
sion in good condition and that the plugs and sockets are not wet.
Connect the mixer socket on the electrical panel to the mains
(fig.5).
13
- Ensure that the power supply voltage, mains frequency

Publicidad