8 . C O M P U T E R I N T E R F A C E
To prevent from brutal computer system shutdown, connect a serial cable or the USB cable
(provided) to your computer. You can then install and use the UPSurf Control automatic
shutdown software which CD-ROM is included in your package.
The USB and RS 232 interfaces at the back of the UPS may alternatively be connected to
the computer. Both communication ports enable the computer to directly control UPS status.
The main functions are as follows:
- Transmission of a visual alarm in event of power failure
- Automatic file closure prior to the battery going flat
- Computer & UPS shutdown
For more information, go to the website :
NB : To install the software you'll need this serial number : 511C1-01220-0100-478DF2A
9 . P R O T E C T I O N T E L E P H O N E / F A X / M O D E M L I N E
If you wish to protect a fax or a modem, connect the telephone cable from the wall outlet to
the "IN" jack. Connect the RJ11 cable (provided) from the "OUT" jack to the fax or modem.
Caution : The telephone line lightning arrester could be rendered inoperable if improperly
installed. This surge protection device is for indoor use only. Never install telephone wiring
during a lightning storm.
If you want to protect a network, use a RJ45 cable (cable not provided).
NB: The UPS functions properly even if you do not use this fax / modem protection option.
1 0 . B A T T E R Y
The battery is the only UPS component which is not in permanent use. It has a useful life of
approximately 3 to 5 years. However, frequent major discharges or exposure to
temperatures over 20°C will shorten its life span. We therefore recommend that users
recharge the battery once every 3 months when the unit is not in use in order to compensate
for natural discharging. UPS backup time will depend on the powered load, as well as the
age and condition of the batteries.
WARNING!
Batteries should always be replaced by qualified technicians. Batteries have a very
high short circuit current: connection errors could cause electric arcs resulting in
serious burns.
INFOSEC UPS SYSTEM - 4, rue de la Rigotière – 44700 Orvault – FRANCE - www.infosec-ups.com
Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 10 06 04 206 10
All manuals and user guides at all-guides.com
www.infosec-ups.com
7