Descargar Imprimir esta página

Proteco Advantage Manual De Uso E Instalación página 7

Ocultar thumbs Ver también para Advantage:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SAFETY CRITERIA
1
Attention: before beginning any kind of procedure of installation is absolutely
necessary to read all this manuall.
2
Test/Control that the performances of the actuator auswer to your installation
needs.
3
Besides control that:
• The gare hinges are in good conditions and perfectly fattened.
• The gate has mechanicall stops in the opening and the closing.
INSTALLATION ADVICE
Connections:
See the "Scheme functional " and refer to the control central scheme.
The electric cable in the exit from the actuator must be tight, but do an ample curve
towards the bottom in order to avoid the reflux in the inside of the actuator itself. (Fig. Q)
The adjustment must be effected when the device has no power supply.
Foresee a omnipolar breaking device near to the apparatus (the contact must
measure at least 3 mm).
Always protect the power supply using a 6A automatic switch, or a 16A single-phase
switch fises.
The power supply lines the motors, to the control unit and the connection lines to the
outfits must be separated to avoid troubles which could generate problems in the
installation working.
Any outfits (of control or safety) eventually connected to the control unit must be
tension free.
Spare parts:
Use esclusively original spare parts.
The batteries should be put with industril waste and not with domestic refuse .
(Law n. 475/88).
Installation:
In order to use correctlythe product and to exclude the possibility of injury or
damage, refer to the "Generals" page enclosure, which is an integrated part of this
manual.
The use of this equipment must be in observance of the safety standards in force in
the country where it is installed, as well as the standards governing proper
installation.
Together with this manual is provided a label showing manufacturer's name and
product reference: please stick it insight on the equipment for future reference.
Warranty:
The warranty supplied by the manufacturer becomes volid in the event of
interference, carelessness, improper use, lightening damage, power surges or use
by unqualified personnel.
The warranty will also become in the following event: Failure to observe the
instructions given in the manuals supplied with the product.
The application of any part in a manner differing from that provided for current
legislation or the use of spare parts which are unsuitable and/or not approved by
manifacturer.
The manifacturer cannot be helb responsible for damages due to impropre or
unresonable use.
INSTALLATION INSTRUCTION SEQUENCE
1
Before the installation, analyse the risks referring to the chapter "Generalities" of
this instructions manual, fill the technic table and eliminate the risks noticed.
In case of more risks, foresee the installation with security system.
2
Test the security laws of the "Security Criteria".
3
Identify the right actuator and left actuator.
4
Controll all the components.
5
Identify the fixing point on the gate and then on the pillar.
6
To lock the "Anchor plate" at the little pillar.
7
To lock the gear motor at the "Anchor plate".
8
To unclamp the actuator.
9
To put the articulated arm.
10 To lock the clamp S3 at the gate.
11 Strech the wires as in the "Functional swing gate scheme".
12 Connect the central and all the accessoires
13 Program the radio receptor
14 Program working times
In case of badworking, see the "Anomalies and advises".
If you do not find any solution call the nearest Assistence centre.
ELECTRO LOCK
Please notice that the electric lock must be installed on the swing that opens first and
must be connected with the terminal board of the control unit.
Position of the electric lock: (Fig. B)
Position 1: Lock between the wings
(in this case is necessary to use the bolt RT15 on the second wing).
Position 2: Lock in the floor (in this case the utilisation of the bolt is not necessary).
Remember to remove the lock or at least block the lock in opening position and take
away all the bolts of lock.
RIGHT OR LEFT ACTUATORS ACTUATORS (Fig. A)
The actuators are supplied in Right or Left version.
Right or left are established looking the gate from the side where the actuators are
installed, if the hinges are on the right the actuator is right, if they are on the left the
actuator is left.
Conseguentely the actuator must be installed with the exit pin, positioned in the hinges of
the gates.
ENGLISH
DETERMINATION OF FIXING MEASURES
To determinate the clamping point it is necessary pay attention to this:
A = 300 mm (Fig. C)
Maximum dimension betwen the axis of the gate and the edge of the pillar.
B = 30 mm (Fig. C)
Maximum dimension from the anchor plate to the edge of the pillar.
(to avoiod the possible brake of the edge)
D = 14 mm (Fig. F)
Vertical distance from the clamping point of the clamp S3 on the gate, to the anchor
plate on the little adge.
Gate fixed in the middle of the pillar (Fig. D)
In this case the maximun al opening corner of the gate is 90°.
In this case the gate can be opened with a corner greater than 90°.
Pay attention to this: growing the distance of the actuator from the edge of the pillar
measure B, the opening angle of the gate grows.
Calculate the height of the actuator installation according to the gate's shape and the
fastening possibility.
a)
If the gate has a big structure you can position it at any highness with no limits.
b)
If the structure is light is necessary to put the operator as muca as possible to the
centre of the gate (in heigt).
Position 1 Central beam of the gate
Position 2 Stiffen of the gate
To dawel or to soldel the anchor plate on the little pillar near to the gate, paynig attention
to the quotes indicate above.
In case of clamping with expanding loose pieces, use metallic loose pieces Ø 13 mm and
consider that the loose piece has to be positioned at 30/35 mm distant from the edge of
the little pillar to avoid the possibility of broke.
In case of wolling pillar use chemichal loose pieces, or resine loose pieces, or a
connectly wolled clamp.
It is possible to use the plate, in two different ways, for right or left actuator, according to
the particulary exigences. (Fig. H / I)
MOTOR POSITION AND ARTICULADED ARM
1
Put the motor on the anchor plate, paying attention to the exit pin of the motor which
must be turned to the interior of the gate.
2
Put together the three parts of the articulated arm. ( Fig. M)
The upright arm with the arm, and the arm with the clamp S3 with screws T.E. 12x35,
self loking huts M12 and wasther Ø 12 mm.
3
Unclamp the motor using the normal key. (Fig. L)
4
Fit the articulated arm into the motor shaft (picture L) and fix it through the TE bolt
8x16 and the Ø32 washer.
5
Extend the articulated arm till to positionate the fixing clamp S3 on the gate.
The best situation is given when the arm forms a little angle as shown in Fig. C.
6
Weld screw the clamp S3 to the gate.
LIMIT SWITCH REGULATION (fig. R)
1
Set the motor thrust
2
Give an opening impulse.
3
When the leaves reach the opening mechanichal limit switch it is necessary to place
the Cam of the micro limit switch and to fix it screwing it down without forcing.
4
Give a closing impulse.
5
When the leaves reach the closing mechanichal limit switch it is necessary to put the
Cam of the limit switch and fix it by screwing it without forcing.
6
Regulate the motor thrust (as per the control unit instructions) It is possible to Stop
the working stroke of the gate with a force of 150N (about 15 Kg)
N.B. This kind of motor has been studied to be used with micro-limit swith.
If you do not use them unclamp the motor can be more difficoult and you could have
a more rapid damage of the mechanical parts.
At this point you need to position the machanical Stop to proced respectively, to the
wing's closing and opening Stop.
If the gate opens till the exterior it is possible to put the actuator between the two pilar.
Gate fixed in the middle of the pillar (Fig. N)
In this case the maximun al opening corner of the gate is 90°.
Gate fixed on the edge pillar (Fig. O)
In this case the gate can be opened with a corner greater than 90°.
Pay attention to this: reducing the distance of the actuator from the edge of the pillar
measure A, the opening angle of the gate grows.
-
To keep out the cap on the fore part of the motor. (Fig. L)
-
To put and to wheel of 90° in time sense the endowed key.
Not it is possible to open and to close the gatem handly.
-
To re-hook the actuator, to wheel in the contrary sense the endowed key.
It is not necessary the gate is in a particurety position, because at the first order all the
volvers are restored.
Gate fixed on the edge pillar (Fig. E)
HEIGHT INSTALLATION (Fig. G)
FIXING THE ANCHOR PLATE
MECHANICAL STOP (Fig. A)
EXTERNAL OPENING GATE.
Exterior fixed the pillar (Fig. P)
RELEASE OF THE ACTUATOR

Publicidad

loading

Este manual también es adecuado para:

Advantage 24Advantage 110vAdvantageAdvantage 12