Setting The Amperage; Control Buttons - Heatworks MODEL 1 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SETTING THE AMPERAGE

IMPORTANT: The factory default current draw is 15 A. To
maximize the amount of temperature rise, be sure to
program your desired amperage to meet your specific hot
water needs. For example, with a fixed flow rate, a higher
amperage setting will result in a higher temperature rise.
Be sure that your MODEL 1 has been installed and wired to
meet the amperage requirements programmed.
CONTROL END

Control Buttons

8
All manuals and user guides at all-guides.com
Outlet / Top
Inlet / Bottom
STEPS
1) Turn on any hot water faucet. Allow the water to run until
all air is purged from the system. This may take two to three
minutes. Water will not be hot.
2) Shut off all faucets.
3) Turn on power to the MODEL 1 by turning on the
associated breaker.
4) After five seconds, press and hold both buttons beside the
display screen of the MODEL 1. (See diagram to the left).
5) Release ONLY the top button. While continuing to hold the
bottom button, press and release the top button five times
until the number "5" appears. The display should start
blinking.
6) Release both buttons.
CAUTION: Breaker must remain off until installation is complete.