ELECTRICAL CIRCUIT DIAGRAM:
NOTE:
Valid electrical circuit diagram for each model
If this device located near to any wall, separation, kitchen furniture,
decorative coating, etc... The distance in between should be 20 cm. and
!
if those are coated with fireproof heat insulating material, the distance
should be 5 cm. It is strongly recommended that fire safety protection
instructions are observed. It is recommended to comply with fire
!
All of the items mentioned below in connection with the installation of
the appliance should be carried out by authorized personnel
1.- Power supply connection of the appliance should be checked by an eligible electrician, and it
should be connected to a fuse at a maximum height of 170 cm.
2.- Power supply connection should be made using 30 mA current leakage fuse as a protection
against current leakage danger.
3.- Power installation of the plugs to be used should be grounded by connecting it to a
grounding bar at the nearest panel.
CODE

INSTALLATION

protections rules
COMPONENTS
S
Hodd switch
ZR
Timer
L
Ultraviolet lampe