It is forbidden to carry out any kind of work
on the pressure vessel and piping, this
covering welding and constructional
changes, etc. Breaking this rule means
extreme danger for you and your col-
leagues.
Attention! If the pressure vessel is operated
at temperatures over 60°C, suitable protec-
tion to prevent contact must be provided.
A pressure gauge that shows the opera-
tional pressure must be installed in the unit.
Depressurize the system before carrying
out any work on the pressure vessel.
Clean the piping before carrying out the
installation work.
The unit must be installed vertically in the
piping.
Ensure that the pressure vessel is installed
without any stresses.
Disconnect the power supply when carrying
out electrical work.

Appropriate use

The equipment may only be used for its
intended purpose. The equipment has been
built exclusively:
For operating media of group 2 as per
Pressure Equipment Directive 97/23/EC.
To separate out microbiological organisms
so as to produce 100% sterile compressed
air.
For the filtration of saturated steam.
Any other form of use or one going beyond
this shall be considered as inappropriate.
We shall have no liability whatsoever for any
damage incurred as a result!
Notes on starting up
PICTURES 1 - 10 (single)
PICTURES 1 - 10 (multiple)
Before initial commissioning
The filter elements are not already installed
in the state in which they are supplied!
All the screwed connections of the pressure
vessel must be done up to the required and
max. permissible tightening torques for the
screws and bolts.
Make a visual check! There must be no
external damage visible.
Make a check for leaks!
Initial commissioning
Slowly apply pressure to the system by
first opening the downstream valve (9).
GB