MODEL:
ZOM-S-20/B/C
ZOK-S-20/B/C
ZPK-S-20/B/C
ZPP-S-20/B/C
ENG |
INSTRUCTIONS
Before using or installing the product, kindly read the instructions and follow safety rules. Installation should be provided by
qualified person or company.
Thank you for choosing the item of company PANLUX s.r.o.
Technical data
Recommended installation height: 2,5m
Location: interiors, exteriors
Material: plastic PP/PMMA
Notice
Before using, check the product and make sure it is not damaged, otherwise do not use it. Before every manipulation make
sure that mains electrical supply is disconnected. In case of damage do not repair or disassemble the product. For the best
functional results, move toward the sensor (see to pic. 6). The incorrect function of the product can be caused by interruption
of electromagnetic field, small temperature difference between moving object and surroundings, reflection (e.g. strong
luminous source). Before replacing the light source switch off the light and let it cool down. Kindly use only recommended
light sources (max. 60W). Do not use small size fluorescent bulbs (diameter smaller than 60mm).
Infringement of any mentioned instruction can cause harm to health or property.
Accessories:
Reserve globes (200mm | 84mm - scorll diameter) – milk (ZOM-200), smoked (ZOK-200), prisma smoked (ZPK-200), prisma
transparent (ZPP-200)
Installation
1
2
plastic ball
light source
82 mm
lampholder
103 mm
240 mm
200 mm
All manuals and user guides at all-guides.com
3
terminal block
case
sensor
230V
MAX
E27
~50Hz
60W
Principle of PIR sensor
PIR sensor receives infra-red waves emitted by objects in reach radius. With movement in the detection area sensor notices
the change and initiates trigger order „Light on" for adjusted time.
Reach setting (sensitivity) – SENS (max. 8m, adjustable)
Reach is to be understood as the area traced out by angle of detection and min. to max. available distance from sensor.
Reach can be changed by knob.
Time setting (switch-off delay) – TIME (10s (±5s) to 4min (±1min), adjustable)
The countdown of adjusted time begins after last detected movement. We recommend setting this function on minimum
during functional the test.
Twilight setting (response threshold) – LUX (10-200lx, adjustable)
We recommend setting this function on maximum during the test.
Stated information may differ according to position and installation height.
Position marked - or applies to minimum and position marked
Warranty voids, if the product is mechanically damaged or connected unprofessionally.
4
L
brown
N
blue
blue
L´
black
black
LUX
TIME
SENS
IP33
3x1,5mm
or
applies to maximum.
+
5
6
130°
220˚
60°
max. 8m
2,5m
All rights reserved
Technical data can be changed without previous notice.
PARK S
0,550kg
2
7
UM_PARK_S_151020