Battery Pack - Metabo NMP 18 LTX BL M10 Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
Already stored numerical values are accessed
as follows:
- If the plus and minus button is pressed at the same
time for longer than two seconds (> 2 sec), you
can access the programme memory to load a
numerical value.
- By pressing the plus or minus button, a previously
stored numerical value between P0 and P9 can be
selected.
- After pressing the S-button (7) again (> 1 sec) the
selected programme is loaded and the
corresponding force appears.
The storage or loading process can be interrupted
at any time by pressing the plus and minus button
simultaneously (> 2 sec).
The mount (5) must not be used for fall
protection.
6.5

Battery pack

Charge the battery pack (11) before use.
Recharge the battery pack (11) if performance
diminishes.
Instructions on charging the battery pack can be
found in the operating instructions of the Metabo
charger.
Li-Ion battery packs "Li-Power, LiHD" have a
capacity and signal indicator (12):
- Press the button (13); the LEDs indicate the
charge (12) level.
- If one LED (12) is flashing, the battery pack (11) is
almost empty and must be recharged.
6.6
Removing and inserting the battery pack
Removing:
Press the battery pack release (10) button and
remove the battery pack (11).
Inserting:
Slide in the battery pack (11) until it engages.
7. Use
7.1
Threading on the blind rivet nut
- Position the blind rivet nut without canting on the
threaded mandrel (1).
- It is recommended that the blind rivet nut be
unscrewed by hand approximately ½ turn to
facilitate threading of the threaded mandrel (1).
- Start the setting process by pressing the switch (9)
.
- Keep the switch (9) pressed until the setting
process is automatically terminated. During the
entire setting process hold the blind rivet nut
against twisting. After the setting process, the
blind rivet nut must be in correct contact with the
nose piece (2). Otherwise, correct the setting of
the threaded mandrel length (see point 6.2).
If the switch (9) is released too early, the
nut will be removed again!
7.2
Manual removal of the blind rivet nut
- If e.g. the blind rivet nut is not positioned correctly
during the threading on process or if the thread of
the blind rivet nut is defective, the blind rivet nut
will not be positioned correctly on the nose piece
after threading on. In such cases, the blind rivet
nut can be removed and changed by tapping the
switch (9) very briefly. We do not recommend to
continue using a damaged blind rivet nut.
- If the setting force selected for a nut size is
considerably too high (incorrect setting!), the blind
rivet nut and the nut thread may be severely
deformed, resulting in extremely high removal
forces. This can lead to the threaded mandrel of
the rivet nut gun not being able to be removed and
the tool switching off due to overload. The
overload is shown as error message "E3" on the
display and by rapid flashing of the illuminated
ring. In such cases, remove the battery pack.
Afterwards, the threaded mandrel (1) must be
removed by hand. To this end, insert the enclosed
hexagon screwdriver AF 4 into the hexagon
socket (16) at the rear end of the tool and carefully
loosen the threaded mandrel (1) by turning it to the
left (see fig. 5).
- After unscrewing the deformed nut, the battery
pack is pushed back in . After pressing and
releasing the switch (9), the tool moves back to
the front end position in a slow reference
movement.
- The last set value for the tractive force appears
again on the display.
- Attention: Now set the correct setting force (see
point 6.3).
7.3
Inserting a blind rivet nut
- Insert the correctly threaded on nut with the rivet
nut gun until the stop into the hole of the
workpiece.
- Trigger the setting process by pressing the switch
(9).
Hold the switch (9) until the setting process
has been completed and the release process
is started automatically.Afterwards the switch (9)
can be released.
Incorrect setting process with error message
E1:
If the setting process is interrupted before the set
setting force is reached by prematurely releasing
the switch, the setting process stops and the tool
automatically returns to the front end position,
whereby the mandrel is removed from the
incorrectly set nut. Error message "E1" appears on
the display. The error is indicated visually and
acoustically be rapid flashing of the illuminated ring
(4) and rapid beeps. The tool cannot be operated
until the error and the corresponding displays are
acknowledged by pressing the S-button (7) (> 1
sec).
- The display now shows rS (reSet). In this mode,
the incorrectly set nut can be readjusted at
reduced speed until the nut is set correctly. To this
end, thread on the already set nut again (see 7.1)
and keep the switch (9) pressed again until the
ENGLISH en
11

Publicidad

Tabla de contenido
loading