Ozone lamp
After approximately one year of continuous use, the ozone lamp needs
to be replaced as its capability to produce ozone has decreased. The
"Replace O3" indicator will show on the display when the ozone lamp
needs to be replaced. Below, instructions regarding how to order and
change the ozone lamp will follow.
Remove/insert ozone lamp
Make sure
the product is
disconnected from
power.
Open the rubber
protection labeled
O3 on the bottom
of the product and
loosen the screw.
Pull the lamp
holder straight out
from the product.
E N
18
Turn the lamp to
the left then pull
straight out.
To install a new
lamp, reverse the
process.
Reset the hour count
by pressing menu
and timer button
simultaneously
until "Replace O3"
disappears.
Order new ozone lamps
Ozone lamps can be ordered directly from Ozoneair. Use of parts other
than those supplied by Ozoneair will void any warranties.

HEPA filter

After approximately 6 months or 5000 hours of use, the HEPA filter
needs to be replaced to maintain an accurate cleaning level and for the
machine to run at its optimal.
Remove/insert HEPA filter
Pull the fabric
straight out to
detach the outer
protection.
Remove the filter.
Insert a new filter,
ensure the filter is
inserted the right
way.
Attach the outer
protection.
Reset the
filter count by
pressing menu
and fan button
simultaneously.
Order new HEPA filters
HEPA filters can be ordered directly from Ozoneair. Use of parts other
than those supplied by Ozoneair will void any warranties.
NOTE - There is a metal prefilter attached to the outer
protection to remove larger dust particles and hair.
This can be cleaned with a vacuum cleaner or by gently
washing with detergent and water.
E N