• The cable reel must be fastened to a stationary surface.
• The unit must be connected to an electrical installation compliant with the NFC 15100 standard. Electrical protection devices
matching the unit's electrical power rating must be fitted upline from the reel.The electrical power rating of the reel is marked on
the label on the enclosure.
The selection and use of components have been carried out taking into account the operating conditions and life span of the machine.
Install the machine in such a way as to avoid any danger to exposed personnel provided that it is properly used. No protection or
warning will be ever sufficient if the operator fails to take certain precautions, if the machine is not maintained in the best operating
conditions and if the following recommendations are not complied with. Before starting work, learn how to use and adjust the machine
correctly. Check that the operator works safely and thoroughly knows the operation of the machine. Avoid exposing yourselves and
anybody else to unnecessary risks. Insist on having personal protection systems used wherever prescribed. Do no remove, modify
or inhibit any SAFETY DEVICE installed by the manufacturer, and check that they are not removed or rendered less effective.
Constantly check that the equipment is perfectly efficient without any anomaly which might damage persons or things. Work in
tidy, risk-free premises with adequate lighting and room. Keep any unnecessary tools or other objects away from the working area.
Install the cable coiler in the places provided by the regulations in force concerning electric systems and work environment.
Fix the cable coiler to wall, ceiling or floor according to the installation diagrams by means of suitable screw anchors or
screws to be fitted into the appropriate holes on the brackets. The electric connection shall be carried out by skilled personnel.
For the wiring harness use a cable having a section suitable to connect the wires and follow the indications on terminal labels:
YELLOW GREEN = ground wire N blue = NEUTRAL WIRE
Fix the feeding cable by means of the cable fixing bridge checking that a proper tensile strength is guaranteed without affecting
the cable integrity.
Additional information and specific connection diagram for each coiler are supplied separately. For cable coilers that are not fitted with
a thermal protector provide before the machine an amperometric protector which breaks all the phases and whose characteristics
coincide with the maximum load shown on the label. Further use of the cable reel may be impaired when exceeding the maximum load.
The cable coiler is equipped with a spring for cable winding. This mechanical device is constantly in operation; therefore make
sure that both during winding and unwinding the cable is accompanied during its movement and NEVER left free. If used on an
automatic machine, appropriate guards shall be installed in order to prevent any damage to persons or things in the event of any
cable or spring breakage. The cable coiler is provided with cable blocking device at every turn of the coil. When working with cable
unwound and ratchet stop on, make sure that the cable is not accidentally touched (the catch may be released and the cable may
wind up uncontrolledly).
Periodically check the perfect efficiency of the cable and that no cut or abrasion has occurred on the insulator which might affect
insulation or functionality. Clean the cable by means of a cloth soaked in hot water to remove dirt and incrustations and guarantee a
perfect rewinding. Do not use any detergent or solvent which might turn out to be incompatible with the cable coiler materials. In the
event that an intervention on the electric or mechanical parts should be necessary or the cable should be replaced, call a licensed
assistance center. Any disassembly carried out by unskilled personnel might entail serious risk mainly due to the pre-loaded spring.