HQ EL-GD10 Manual página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Gas leak alarm state
Gas concentration in a normal range
Display "1,2,3" and "STATE" LED is green.
Gas concentration slightly high
Display "3,4,5" the "STATE" LED is yellow and the alarm sounds slow "Di--Di".
Gas concentration high
Display "6,7,8,9" the "STATE" LED is yellow and the alarm sounds quick "DiDiDI--DiDiDi".
Gas concentration reached preset Lower Explosive Level (3%~20%)
Display "A", "STATE" LED red, "ALARM" LED lights red and alarm sounds.
Maintenance
To keep the detector working properly, following is recommended:
1. Test the detector once a week e.g. press gently a lighter (without ignition) in front of the
detector close to the gas hole.
2. Keep the detector free of dust by gently vacuuming.
3. Don't paint the detector.
4. Don't spray aerosol on or near by the detector.
5. By refurbishing rooms store the detector in a poly bag.
Important! What to do when the alarm starts
Keep calm and carry out the following actions (not necessarily in the order given)
1.
2. Turn off all gas appliances.
3. Don't switch on or off any electrical equipment including the El-GD10
4. Open doors and windows to increase ventilation.
5. Don't use a telephone where the presence of gas is suspected.
If the alarm continues evacuate immediately the premises and contact the 24 hour
emergency service of the gas supplier.
Detectable gases: LPG, natural gas and town gas
Power supply: 100VAC - 240VAC ~ 50/60Hz
Power consumption: < 4W
Alarm level: 3%LEL~20%LEL
Alarm volume: > 85dB
Temperature range: -10°C ~ 50°C
Relative humidity: < 97% RH
Storage temperature: -25°C ~ 55°C
Dimensions: 67 x 67 x 112mm
Weight: 122g
2

Publicidad

Tabla de contenido
loading

Tabla de contenido