Control stages. Allows you to select the element you wish to heat or cool the zone.
•
Air. Only the air stage works.
•
Radiant. Only the radiant stage works.
•
Combined. The system combines the use of the air and radiant stages to reach the
comfort temperature quickly and efficiently. This is the default setting.
Q-Adapt. Allows you to define the airflow control algorithm that best fits the duct
installation. The options available are:
EN
•
Maximum: the system operates at maximum speed regardless of the number of zones.
•
Power: the system operates at a higher speed than in Standard mode to ensure airflow is
increased.
•
Standard: the system changes speed depending on the number of zones.
•
Silence: the system operates at a lower speed than in Standard mode to improve noise
reduction.
•
Minimum: the system operates at minimum speed regardless of the number of zones.
Note: In case of having a 0-10 V gateway; the algorithm, in addition, will take into account the
minimum and maximum voltage values set by your installer in this menu.
Lite settings. In this parameter, you can define the base set-point temperature for the
zone where the Airzone Lite thermostat is installed. You can also configure the wired Lite
thermostat to act as a wireless thermostat: after a few seconds (during which it indicates
the status of the zone), it will switch off.
Note: To access the Lite settings parameter, from any Airzone Blueface thermostat you must
access the zone controlled by your Lite thermostat using the Zone navigation option.
Purification. Use this option to select the purification operation mode:
•
Auto. Purification is activated when the system is in air demand and, in addition, the
Indoor Air Quality (IAQ) measured by the particle sensor is not Good. The zone will
automatically stop purification when the zone has had a Good IAQ measurement for
more than 5 minutes.
•
On. Purification is always on whenever there is air demand.
•
Off. Purification is not activated.
8