EN
ES
Operation and storage
To turn on the heater:
1. Turn on the valve on the gas supply cylinder completely.
2. Press and turn the variable control knob to PILOT position (counter-clockwise 90º).
3. Press down the variable control knob and hold for 60 seconds. While holding down
the variable control knob, press the igniter button several times until the pilot flame
lights. Release the variable control knob after the pilot flame lights.
Note:
- If a new tank has just been connected, please allow at least one minute for the air
in the gas pipeline to purge out through the pilot hole.
- When lighting the pilot flame make sure that the variable control knob is continously
pressed down while pressing the igniter button. Variable control knob can be relea-
sed after the pilot flame lights.
- If the pilot flame does not light or it goes out, repeat step 3.
4. After the pilot flame lights, turn the variable control knob to maximum position and
leave it there for 5 minutes or more before turning the knob to desired temperature
position.
Warning: check that no broken on the glass is found before operation
To turn off the heater:
1. Turn the variable control knob to PILOT position.
2. Press and turn the variable control knob to OFF position.
lgniter
igniter
3. Turn off the valve on the gas supply cylinder completely.
Storage
1. Always close the gas valve of the gas cylinder after use or in case of disturbance.
2. Remove the pressure regulator and the hose.
3. Check the tightness of the gas valve and for damage. If you suspect a damage,
have it changed by your gas dealer.
4. Never store liquid gas cylinder in a subterrain, or at places without adequate air
ventilation.
11
Variable control knob
Off: The heater stop work
Hi: Maximum temperature
Lo: Minimum temperature
Fig.2. Heater control
Egypt