Adjustable device properties when commissioning:
• Installation location of the volume measuring section in the outlet (
corresponds to graphics
!
The installation location may only be re-programmed during commissioning. The
table below is valid as a locking condition. Afterwards, the device properties can
no longer be changed.
[L/pulse]
RW 10 [L/pulse]
RW 100 L/pulse
Ambient conditions
Installation
• Electrical and magnetic fields can disturb electronic components in the energy meter.
Ensure sufficient distance (approx. 10 cm) between the calculator and possible electro-
magnetic sources (e.g. transformers, electrical motors, etc.).
• Select a dry, easily accessible location.
• In non-condensing environments.
• In closed rooms.
Operating conditions
• Protection class
• Ambient temperature
Storage conditions:
• Ambient temperatures
Radio (if activated)
• Transmission frequency: 868.95 MHz; transmission power: < 25 mW
Installation
General installation instructions
• Observe the environmental conditions!
• Do not carry out any welding, soldering or drilling work in the vicinity of the meter.
• Only install meters in operational systems.
• Protect meters against damages from impacts or being hit.
• In order to guarantee the corresponding meter protection class, it must be ensured that
the cable outer diameters for all connection lines (supply cable, temperature sensor
cable, MBUS and pulse cable) lie between 3.9 and 4.9 mm.
1
,
2
and
3
) or programmable for the inlet flow.
Installation location changea-
ble until Energy progress...
0.1 MWh
1 MWh
IP 54
Θ: +5 °C...55 °C
Θ: -25 °C...70 °C
) (delivery status
Installation location changea-
ble until Energy progress...
0.36 GJ
3.6 GJ