4. Connect the blue wire for the light kit to
the black household wire.
5. Turn the wire connections upward,
spreading them apart so the green
(ground) and white wires will be on one
side of the outlet box and the black and
blue wires will be on the other side, and
push into the outlet box.
CHECK TO SEE THAT ALL CONNECTIONS ARE
TIGHT, INCLUDING THE GROUND, AND THAT
NO BARE WIRE IS VISIBLE AT THE WIRE NUTS,
EXCEPT FOR THE GROUND WIRE.
ELECTRICAL DIAGRAMS ARE FOR REFER-
ENCE ONLY. OPTIONAL USE OF ANY LIGHT KIT
SHALL BE UL LISTED AND MARKED SUITABLE
FOR USE WITH THIS FAN.
All manuals and user guides at all-guides.com
SUPPLY CIRCUIT
WHITE
BLUE
BLACK
WHITE
Finishing the Fan
Installation
STANDARD CEILING MOUNTING
Outlet
WHEN
Box
DOWNROD MOUNTING, THE TAB IN THE RING
AT THE BOTTOM OF THE MOUNTING PLATE
Green
MUST REST IN THE GROOVE OF THE HANGER
Grounding
BALL. FAILURE TO PROPERLY SEAT THE TAB
Lead
IN THE GROOVE COULD CAUSE DAMAGE TO
THE WIRING.
Ground
1. Align the locking slots of the ceiling can-
to
opy with the two screws in the mounting
Downrod
plate. Push up to engage the slots and
turn clockwise to lock in place. Imme-
diately tighten the two mounting screws
firmly.
2. Install the remaining two mounting
screws into the holes in the canopy and
tighten firmly.
3. You may now proceed to attaching the
fan blades.
CLOSE-TO-CEILING MOUNTING
1. Carefully unhook the fan from the
mounting plate and align the locking
slots of the ceiling canopy with the two
screws in the mounting plate. Push up
to engage the slots and turn clockwise
to lock in place. Immediately tighten the
two mounting screws firmly.
Figure 12