Power Jet-Light 3 x 36 W IP 54
6.1
Initial Operation
Step
Activity
1
Plug the standing bracket on to the retaining bracket. Bolt the U-Bolt structure with the
U-Bolts.
2
13
Fasten the lamp body in the middle of the U-bolt structure. For this purpose use the bolt
spacer and the adjusting screw. The light bracket can be set through the adjusting screw.
IMPORTANT: Before the initial operation, check all the bolted connections.
3
Press the ON / OFF switch. The work lamp will be switched on or off accordingly.
6.2
Change Illuminant
DANGER:
Pull the mains plug before opening the work lamp!
Let the work lamp cool before touching it (at least 15 minutes).
Coming into contact can lead to burns.
Step
Activity
1
Set the work lamp on its „back". Press the rubber lip upwards.
2
Screw out the 4 protective covering bolts from the protective cover. Remove the protective
cover.
Operating Manual
6
9
16
3
3
11
2
17
Pos.
Name
6
Standing bracket (U-Bolt structure)
9
Adjusting screw
16
Bolt spacer
13
Casing (Lamp body)
Pos.
Name
3
Protective cover
11
Rubber lip
11
13
Casing (Lamp body)
13
Pos.
Name
3
Protective cover
11
Rubber lip
2
Protective cover bolt
Status: 7201S-07-2007_K