MODEL D
MODEL D Eurorack Installation
The MODEL D synthesizer can be removed from its factory
chassis and installed into a standard Eurorack chassis
(not supplied). The module width is 70HP.
We recommend that this procedure is undertaken only by
experienced service technicians, to prevent personal injury,
or damage to the unit.
The Eurorack case will need its own suitable power supply
unit to power the MODEL D synthesizer.
A 10-pin connector on the rear of the main PCB of the
MODEL D allows the +12 VDC power supply connection
to be made. A 10-pin to 16-pin adapter ribbon cable is
supplied to connect to your power supply.
Before proceeding, make sure that your
power supply is capable of supplying
+12 VDC, 1 Amp.
Make sure that the connections using the
supplied adapter cable will supply the ground
and power to the correct pins of X23.
Procedure
Follow all steps in the order in which they are presented.
1.
Disconnect the power cord and all other
connections to the MODEL D.
2. Undo the 8 screws on the top panel as shown.
There is no need to undo any other screws.
Disconnect from
Main PCB
3. Disconnect the two cables from the lower side
of the main PCB of the MODEL D, and remove the
assembly from the chassis.
4. Store the chassis assembly and the power supply
adaptor in a dry safe place.
5. Securely connect the 10-pin end P1 of the
supplied adapter cable to connector X23 on the
Main PCB of the MODEL D.
X21 No Connection
X23
Supplied Eurorack Power Supply Cable, Part # A74-0001-79446
Connect End P1 to Connector X23 on main PCB
P1
Red Stripe
2
1
10
9
400 mm ± 10
6.
Make sure your power supply is turned
off and disconnected from the AC mains.
7.
Make sure that your power supply will
supply the following to the pins of
connector X23, as shown in the
diagram above:
Pins
Connection
1 and 2
No Connection
3 to 8
Ground
9 and 10
+12 VDC
Pins 1 and 2
No Connection
Pins 3 to 8
Ground
Pins 9 and 10
+12 VDC