2. oPEratING INStructIoNS
2.1. using the Product
Gas connection
• The cooker is provided with a label placed on the rear panel near
the gas inlet showing the type of gas and pressure for which the
appliance has been originally adjusted.
• Before connecting this appliance, check if it is prepared for the type
of gas and pressure available in your home. If not, it is necessary to
convert the appliance to another gas type as indicated in section 2.2.
• All possible gas types and pressures are shown on the data plate
and in table no. 1.
• Butane gas bottles are unable to function in places with low
temperatures, in this case it is advisable to replace the Butane for
Propane gas (operation to be carried out by a qualified installer).
never place a propane gas bottle inside a building.
• You may connect the appliance to a gas bottle fitted with its
respective regulator or to a gas network tap. Since this is a movable
unit, the following types of tubes can be used:
- Flexible rubber or elastomeric tube certified according to the
- Flexible stainless steel tube certified according to the applicable
- Flexible rubber or elastomeric tube certified according to the
Notes:
• Ensure that the tube is not bent or twisted.
• Ensure that the tube is not in contact with the rear panel.
• The tube must be replaced before the expiry date.
• Check that the cable goes along the whole length of the tube.
• The clamps should be adequate for a good tight.
• The maximum length of the flexible rubber tube must be of 1500 mm
The connection lo the cooker must be done
on the same side of the point of feeding, in a
way that the tube does not cross the back of
appliance. If necessary, change the gas inlet
or request technical assistance to adapt the
tube so that the gas entrance is done on the
correct side of the appliance.
after connecting the unit, check for eventual
leaks with a frothy product. Never use a flame.
Fogoes-KGS2981-Kunft-Manual-3.indd 12
applicable standards, fixed to an adequate inlet gas connection
and held tight by a clamp on both ends.
standard, with threaded connections.
applicable standard, with threaded connections.
12