TEST MODE

This function is useful to check the correct communication via radio, and to perform the
wind and sun function test.
To activate the TeST function, hold the SeT button down for around 2 seconds, until the
motor confirms the command by bringing the awning to half opening distance. The test
function lasts for 3 minutes, during which the wind and light level settings can be checked,
without waiting for the activation times. After 3 minutes, the Windtec sensor returns to
normal mode function.
Set button
set
(2 sec)
Wind FunCTion TeST
To avoid errors during the wind function test, we advise setting the motor to manual mode
(wind only). With the anemometer blades moving, when the speed detected by the sensor
exceeds the set level, the motor will close completely the awning. After the awning is
closed and the anemometer blades stop turning, the awning returns to halfway out if the
automatic reopening function is active; if it is not, the awning remains closed.
Sun FunCTion TeST (Windtec Lux)
Check that the motor is set to the automatic mode. When the sensor detects a change in
light intensity, it opens the awning if brighter than the set point or closes it if weaker. This
test can be repeated several times to establish the desired automatic opening and closing
level according to the light.