Incorrect maintenance or use of spare parts other than original spare
parts provided by the manufacturer
•
Alterations to the product without express permission from the manu-
facturer
•
Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product
specifications.
The manufacturer accepts no liability for any injury or damage to the prod-
uct due to frost caused by the user not following the instructions in the
manual.
Using the device
No. in fig. 3,
Description
page 3
1
Control panel
2
LPG combi heater
3
Safety an drain valve
At interior temperatures around 0 °C the safety and drain valve
opens automatically, thus draining the water from the boiler
and preventing the boiler from being damaged by freezing
water.
4
Air inlets
Setting the device
1. Adjust brightness of the control panel display: see fig. 4, page 3.
2. Set max. fan speed in silent mode : see fig. 5, page 3.
3. Set min. fan speed in ventilation mode : see fig. 6, page 3.
4. Set temperature unit: see fig. 7, page 4.
I
NOTE
Silent mode might have impact on maximum available
heat output and function of the water heating.
Setting and using the timers
1. Set and activate coming home timer for air heater: see fig. 8 and
fig. a, page 4.
2. Set and activate sleeping timer for air heater: see fig. 9 and fig. a,
page 4.
3. Set and activate coming home timer for water heater: see fig. 0 and
fig. a, page 4.
4. Change active timer: see fig. b, page 4.
5. Deactivate timer: see fig. c, page 4.
Using favorites
You can save frequently used settings as favorites so they can easily be
selected again later. Up to 6 favorites are possible (A ... F).
1. Save the current settings as a favorite: see fig. d, page 4
2. Select a favorite: see fig. e, page 4.
Flushing the boiler
➤ Proceed according to fig. f, page 4.
Filling the boiler
If the interior temperature is below 0 °C, heat the interior with the heater
first. Otherwise, the safety and drain valve will open and drain the boiler.
➤ Proceed according to fig. g, page 4.
Emptying the boiler
➤ If temperature inside the vehicle is below 0 °C: ensure that the safety
and drain valve has released, see fig. h, page 5.
EN
If the vehicle is not used during the frost period, the boiler must be emp-
tied.
➤ Proceed according to fig. i, page 5.
Start after a long period of non-use
1. Check the cowl and remove the cover and any dirt (e.g. leaves, cob-
webs, etc.).
2. Flush the boiler according to fig. f, page 4.
After a long period of non-use, smoke or odours may develop for a few
minutes due to dust or dirt.
➤ In this case, ensure that the interior is well ventilated and perform self-
cleaning: see chapter "Self-cleaning" on page 7.
Cleaning and maintaining
➤ Clean the device according to fig. j, page 5.
➤ Never use detergents containing chlorine for cleaning and disinfec-
tion.
➤ Perform self-cleaning once a week: see chapter "Self-cleaning" on
page 7.
➤ If side cowl is positioned below a window: Check window switch
operation as a pre trip or seasonal check.
➤ Check regularly, especially after long journeys, that the cowl and the
exhaust duct are intact and correctly fixed.
➤ Operate the safety and drain valve regularly, at least twice a year, to
remove limescale deposits and ensure proper function.
➤ Have the heater, its gas supply, the exhaust duct and the cowl
checked by an expert in accordance with national regulations (e.g. in
Germany every 2 years). If no national regulations exist that should be
done at least every 2 years. The inspection must be certified on a test
certificate (e.g. DVGW Work Sheet G 607 for vehicles in Germany).
Self-cleaning
To clean the system against bacteria operate the heater for a few minutes
at the highest temperature level for self-cleaning:
1. Set room temperature to max. value.
2. Choose auto mode
3. Choose hot mode for water heating.
Replacing fuses
!
WARNING!
Before servicing or changing the fuses, switch off the device,
shut the gas supply and disconnect DC (12 V) supply.
CH4000E, CH6000E only: Disconnect the AC (230 V)
supply.
➤ Replace broken DC fuses according to fig. k, page 5. Only use fuses
with the same value.
Troubleshooting
The display shows up to 4 error codes and warnings.
1. Scroll through the error codes: see fig. l, page 5.
2. Reset error codes: see fig. m, page 5.
3. Reset warnings: see fig. n, page 5.
Alternatively, you can switch off the system by pressing the
for 3 s.