Descargar Imprimir esta página

DS PRO Serie Manual De Instrucciones

Cuentavueltas - crono

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

GENENRAL FEATURES:
10
different race programms (see advanced programming)
4
displays per lane. Easy and quick reading of laps and time
with only one key push.
Time Programming: maximum 10 hours (less 10 seconds),
minimun 10 seconds.
Lap Programming: Maximum 9999 laps, minimum 1 lap.
Programming minimum time gap between 2 laps (to test
motors, calculate top speeds, checking section time)
PERMANENT
programming. Memorize a programm until new
change (keeping the programm even without power on lap
counter)
TOTAL or INDEPENDENT
race programm.
Race start with power on track
light but with power on, when jump the start gets penalized
without counting the lap it does) or without power on track
on, all cars gets the power when green light is on)
All car will stop at the end of race when
(DS.21) or
"PRO stop and go
INDEPENDENT lane control is needed to use "PRO Stop and go
box" because have a double relée included.
Pause key, keeping in memory the actual race time and continue
from it later.
Upgrade up to 8 lanes.
Exit RS-232C to computer with free software and transmision
codes for own software manufacturing
Shows:
- Lap timing each time a car cross the sensor.
- Spend time or left time to end of race, during or at the end
of the race.
- 2 fastest laps per lane during the race or at the end.
- Race timing for each lane (INDEPENDENT mode).
- Timing in 1/10000 of seconds
- Winning lane blinks
- Fastest laps on the race blinks.
Track power control throught control boxes: "Stop & go box"
and
"PRO stop & go
box"
Individual red/green traffic light for visual control of race start.
Beep signals when: programming, start, last lap, end of race,
pause, fastest lap.
Easy connection to own "DS-Card control" system for racing
or rental use.
INSTALLING AND CONNECTIONS:
The main difference of this lap counter and other is the
possibility to grow up in number of lanes untill 8 without the
need of changing the lap counter system at all. The main Ds.300
(lane 1+2) have a connector on the base to connect into the
DS.3340 (lane 3+4) and this into the ds.3560 (lane 5+6) and at
the end to DS.3780 (lane 7+8).
Each 2 lane module have at the back 2 conector to connect
the sensor for the lanes and for the control boxes. The main unit
(lane 1+2) have an extra plug to connect RS.232C directly into
the computer, and to the power unit.
IMPORTANT:
TRACK, CONTROL and INTERFACE connectors needs to be plug
before power (12V) is connected.
Connectors:
TRACK: Let you connect the sensor for lane 1 and 2, different
options are available: dead strip (available on most track systems,
only 1 direction of running), infrared bridges (available on most
track systems and for 2,4,6, and 8 lanes and works in both ways
of running).
1
OPERATION MANUAL
LAP COUNTER - CHRONOGRAPH
DS - 300 "PRO SERIES"
lane control can be selected on any
(time off,
waiting for the green
"stop and go
box"
box" (DS.61) is connected. For
To PC
(RS-232-C): Let you connect the Super-Computer DS.300
into any PC throught a COM (RS-232C) and use the free software
for controlling the races ( is needed the conexion wire DS.0052)
CONTROL: TO connect the control boxes "Stop and Go box"
with one relee (DS.0021), and
double relee for individual lane control (DS.0061).
The control boxes allows a easy connection of controllers, track
power units. Each box is valid for 2 lanes. Independent controller
for each lane can be plugged using international 4mm. plugs .
Used for any controller type (MRRC, PARMA, CARRERA;
SCALEXTRIC, NINCO, etc...) with or without electrodinamic brake.
Traffic light in red/green big LED. Includes all wiring and connectors
for transformer, independent wiring to track (with easy lane
direction change). Control on start and end of race, giving power
to the track when start and cutting the power off when race is
over.
(time
POWER: To connect a power unit for the lap counter, to allow
the control 8 lanes is needed the 3 amp and 12 Volts minimum.
DS manufacturer one power unit for this (ref. DS.0051)
KEYS and FUNCTIONS:
START – STOP KEY:
Allow to start and stop/abort the race. When a race is over
the winning lane blinks and the lap counter stops counting. There
is always 2 second of time just after the end that keep counting
if any car crosses the sensor because of it inertial movement.
Data keys:
During the race:
- If race is programmed at a fixed time: With that key
you can see the race time at the moment (1 st . push) or the time
left to end. (2nd push).
- If race is programmed at laps: Shows laps to end (1 st .
push) or race time until that moment. (2 nd push)
At the end of the race:
- If race is programmed at laps: With total control
shows total time of the race just untill the first car croses the
sensor in the last lap.
With individual control shows the total time of each lane
to cover the fixed programmation.
- If race is programmed at a fixed time: Shows the total
time that the race have been programmed and the time left (0).
If the race is aborted it shows the time spend from start to the
abort (1 st . push) and the time left untill end of race (2nd push).
- If race is programmed in F-1: When the race is over you
can see the lap difference from the winner, with a 1 st . push
shows the time spend on the race on the winning lane (blinking)
and the time spend on the lap after the winner finish on each
lane (indicates who made faster the following lap after the winner.
Shows the best time (1 st . push) and 2 nd best time (2 nd push)
of all lanes. During the race or at the end. If pushes the key
"0000" while the fastest lap is shown you can see the 1/10000 th
of second.
Programming keys
First key to start programming. When pushes you can see
the different race programms:
- Time programation: (P-ti): maximum 9 hours, 59 minutes
and 50 seconds, minimum 10 seconds.
"PRO Stop and Go
LAPS/ TIME:
Clock key.
CHRONOS:
MODE
key:
box" with

Publicidad

loading

Resumen de contenidos para DS PRO Serie

  • Página 1 8 without the can see the lap difference from the winner, with a 1 st . push need of changing the lap counter system at all. The main Ds.300 shows the time spend on the race on the winning lane (blinking)
  • Página 2 - During the race this key works as a pause key, stopping time when the green light is on and activate the relee “STOP the system to count laps and if the “stop and go box” (Ds.21) or and GO“ box (DS.21) or “PRO-Stop and...
  • Página 3 Start-stop functions will only work when “Stop and Go” (DS.21) Start-stop functions will work only when “Stop & go box” (DS.21) “Pro Stop and go box” (DS.61) is connected to the lap counter.
  • Página 4 The final place is fixed with the lap difference and the time difference on the last lap of all them. Start-stop functions will work only when “Stop & go box”(DS.21) “Pro Stop and go box” (DS.61) are connected to the lap counter.
  • Página 5: Funcionamiento Del Teclado

    3 Amperios. Para tal (con tarjeta igual a las usadas en los teléfonos). Para el control fin recomendamos el fabricado por DS a este efecto Ref. DS.51 de carreras, pilotos, alquiler de pistas, etc. ATENCION : FUNCIONAMIENTO del TECLADO Para la alimentación de corriente a este cuentavueltas es necesario...
  • Página 6: Operaciones Avanzadas

    Por tiempo en “on”, entendemos que el tiempo empieza “off”. (Ver Operaciones avanzadas). a contar en el momento que el semáforo enciende el color verde y activa los relés de la caja “STOP & GO Box” (ref. DS.21) o...
  • Página 7 “PRO - STOP & GO SLOT con programación a vueltas. Con la ventaja de que, Box” (ref. DS.61) al cuentavueltas. al utilizar las cajas “STOP & GO Box” (ref. DS.21) o “PRO – STOP & GO Box” (ref. DS.61), los coches se pararán siempre...
  • Página 8 Funciona siempre que esté conectado a una caja “PRO - utiliza en las carreras de F-1 reales. STOP & GO Box” (es de dos relés) (ref. DS.61) Este es el sistema más adecuado para carreras tipo F-1 en Slot. También es el más indicado para alquiler de pistas comerciales ATENCIÓN:...

Este manual también es adecuado para:

Ds-300