Recommended spare parts

The following is a list of spare parts that should be kept ready at hand in order to speed up maintenance
operations.
List of recommended spare parts (fig. 19)
Pos.
1
2
3
4
5
6
7
8

Troubleshooting

Problem
The vacuum cleaner does not
start
The vacuum cleaner does not
vacuum
The vacuum cleaner suddenly
stops
Dust leaks from the vacuum
cleaner
Electrostatic current on the
GB
vacuum cleaner

Manufacturer Service Centre

Please consult the appendix.
C301
Description
Antistatic star filter "L"
Antistatic star filter "M"
Filter ring
Vacuuming unit
Filter ring gasket
Filter clamp
Absolute filter "H"
Antistatic bag
Cause
Lack of power supply
Clogged primary filter
Clogged vacuum hose
Thermal limiter operation
The filter is torn
Inadequate filter
Non existent or inefficient
grounding
Dimension
Ø 360
Ø 360
Ø 360
Ø 360
Ø 360
Ø 170
Ø 360
Check for power at the socket
Check the condition of the socket and
the cable
Ask for assistance to be performed by a
qualified manufacturer's technician
Shake the filter. Replace it if necessary
Check the vacuum hose and clean it
Wait until the vacuum cleaner cools off
(about 120 minutes)
Replace it with another of identical type
Replace it with another of suitable type
and check
Check all grounding, particularly the
union to the inlet; moreover, the hose
must be strictly antistatic
12
Code
8 17140
8 17508
8 15002
4 58015M
8 17226
8 18078
8 17262
8 40874
Remedy