If any of the following conditions occur, turn off unit and breaker immediately.
Power wires are damaged or visibly worn
You smell a burning odor or see smoke
The unit makes a loud or abnormal sound
The unit is tripping the circuit breaker
Water or other objects get inside indoor unit or are coming out of indoor unit
Do not attempt to fix the above issues yourself. Contact qualified person(s) for repair.
Issue
Circuit breaker may be tripped or shut off
Unit does not run
Batteries in remote control may be dead
Power failure
Emits peculiar
Odor may be coming from outside source not related to unit
odor
Filters may need to be cleaned
Can be formed in high humidity areas where there is a large
Emits light mist
difference between the room's air and the conditioned air
May be expansion & contracting due to change in temperature Normal function
Emits noises
May be caused by refrigerant gas flowing through the unit
Temperature setting may be higher than ambient temperature
Air filters are dirty and may need to be cleaned
Air inlets or outlets may be obstructed
Poor cooling
Shades or curtains are allowing too much solar heat in
performance
Doors or windows may be open
Too many sources of heat in room: lights, electronics, people,
etc
Low refrigerant due to leak or long term use
Outdoor temperature is extremely low
Poor heating
performance
Cold air is entering through doors or windows
Low refrigerant due to leak or long term use
Too much or too little refrigerant in system
Excess moisture has entered the system
Unit starts &
Compressor has failed
stops frequently
Voltage is too low or too high
Troubleshooting: 4.0
Possible Causes
4
Solution
Reset circuit breaker
Change remote batteries
Wait for power to return
Verify odor source is external
Clean filters
Will go away as unit runs
Normal function
Adjust temperature setting
Clean filters
Remove obstructions
Close shades or curtains
Close doors or windows
Turn off uneccessary electron-
ics, lights
Contact installer for recharge
Use separate auxiliary heater
as needed
Close all doors and windows
Contact installer for recharge
Contact installer for recharge
Contact installer for service
Replace compressor
Contact power company or
local electrician

Publicidad

loading

Productos relacionados para Hessaire H Serie

Este manual también es adecuado para:

H12e1H18e2H12hp1aH18hp2a