Operating mode 3

via national network with 230 V ~
The 230 V ~ national network is looped through from connec-
tor (a) to connector (c) via a relay in the power inverter. The
power inverter remains switched off. The air conditioning unit
can now be operated at any cooling setting.
a
c
The air conditioning unit with power inverter switches itself off
in the following cases:
National network failure.
National network input voltage connector (a) is
disconnected.
The red LED on the IR receiver illuminates. The air condition-
ing unit must be switched off and on again via the remote
handset.
If the 230 V ~ national network fails, the power inverter is not
automatically switched on again in order to prevent unwanted
battery discharging.

Technical data

Determined on the basis of EN 14511 and the Truma test
conditions.
Designation
Saphir vario, Comfort air conditioner
Area of operation
Small areas, mobile and stationary
Dimensions (L x W x H)
800 x 550 x 200 mm
Weight
28 kg
Power supply
230 V – 240 V ~, 50 Hz
Maximum cooling capacity
2.0 kW
Start-up current
20 A (150 ms)
Power consumption
1.7 A – 4.4 A
Protection mode
IP X5
Volume flow (cold air)
max. 370 m³/h
Cooling agent
R 407C and R 134a
Cooling agent content
see name plate on unit
Maximum inclination of vehicle during operation
5° / 8 %
Operational limits
+21 °C to +40 °C
Below +21 °C an ambient air sensor prevents the operation
of the compressor.
An icing sensor prevents impermissible formation of ice on
the evaporator.
A temperature switch pre vents excess current flow and
excess temperature at the compressor.
16
EEC type approval
The Saphir vario complies with the interference suppression
directive 72/245/EEC for vehicle engines with annexes
2004/104/EC, 2005/83/EC and 2006/28/EC and bears
type approval number: e1 03 4392
Right to effect technical modifications is reserved!
Funktion diagram
Supply air
Compressor
infeed from
the outside
Condenser
Fan
Supply air
Throttle
discharge to the
outside-downwards
High-pressure side

Installation dimensions

365
150
HW
LE
112
Saphir vario
HW
The dimensions are in mm.
Circulating
air suction
form inside
Low-pressure side
800
186
65
LA
45°
KO
Cold air
outlet
intake