Cod. 970073EIPb V04_21
Click on Run and when you finish, click on Close.
M
R
EMORY
ESET
Memory Reset procedure erases all low level configuration settings including communication key (none)
and default IP address of the Controller Unit (192.168.0.213).
Memory Reset Procedure:
1. Remove power supply.
2. Short CLK and IN4 lines.
3. Restore power supply (all LED will flash) and wait min. 6s.
4. Remove connection between CLK and IN4 lines (LEDs stop flashing, LED2 is ON).
5. Wait (approx. 1.5 min) till moment when LED5+LED6+LED7+LED8 will flash what indicates
that memory has been restored to the defaults.
6. Remove and connect again power supply.
7. Once the memory has been restored to its default values, it is necessary to perform a low-
level configuration and re-establish a new communication key (e.g. 1234).
8. AC-MAX LT/ST-Right-click on the controller Commands-Set communication key. Enter twice
the same password 1234, 1234 and check.
EN
13/30