Attention! The fitting must be installed, flushed and
tested after the valid norms.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water, swivel to the right =
cold water.
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
Hot water temperature:
Recommended hot water temp.: 65° C
Rate of flow 0,3 MPa:
Test certificate
14615XXX/15615XXX/
31655XXX/32655XXX/
32675XXX/33655XXX:
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Fault
Mixer stiff
Mixer dripping
Diverter not operating
Hot water temperature too low
No cold water
Instantaneous water heater
starts up when cold water is
selected
English
max. 1 MPa
1,6 MPa
max. 80° C
approx. 32 l/min
WRAS
0209009
Cause
- Cartridge defective, calcified
- Cartridge defective
Sedimentation
- Water pressure to low
- Diverter defective
- Hot water limiter incorrectly set
- Crossflow
Spare parts (see page 3)
1
handle Metropol
1.1 screw cover
2
handle Mondial
3
handle Metris
4
handle Sportive
4.1 screw cover
5
handle Talis S
6
handle Talis E
7
handle Fcus S
8
handle Focus E
9
escutcheon
10
flange
11
fixing screw
12
sub plate
13
nut
14
locking screw
15
seal
16
noise reduction
17
cartridge cpl.
18
extension set 25 mm
19
extension set 22 mm
XXX = Colors
000 chrome plated
090 chrome plated/gold plated
810 satinox
®
880 satin chrome
Remedy
- Exchange cartridge
- Exchange cartridge
- Increase water pressure
- Exchange diverter
- Set hot water limiter
- Exchange seal (15),
14092X X X
96338000
15092XXX
31092000
32091000
94191000
32092000
33091000
31793000
31791000
96452XXX
95010XXX
96454000
96447000
95007000
96059000
95008000
94073000
92730000
13595000
13596XXX
o-ring seal (15.1)
7