Scan Temperature Deviation; Example Of Use - Powerfix Profi 291541 Instrucciones De Utilización Y De Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Use this method to select the tolerance range indicated below the display:
OFF

Scan temperature deviation

S elect a reference temperature as described above.
P ress the Measure button
wish to measure. The temperature is indicated in the display
H old the measure button whilst scanning, and slowly and steadily move the
laser dot across the surface you wish to measure. The temperature deviations
between the reference value and the measurement are indicated as follows:
Visual
indication
Red display
background
Green display
background
Blue display
background

Example of use

To e.g. test cold air entering the space between a window frame and brickwork,
first scan the temperature along the entire frame, next to the closed window. Select
the warmest area of the frame as the reference temperature, then e.g. a temperature
variation of 3 °C / 5°F.
Now steadily scan again, along all sides of the window, next to the frame. The
blue colour display and a slow tone series indicates a possible influx of cold air
with a difference of 3 °C / 5°F.
52 GB/MT
0.5 °C
1°F
and aim the laser pointer
3
Acoustic
indication
Rapid tone series The upper temperature threshold has
No tone
Slow tone series
3 °C
5°F
Cause
been exceeded
Within the temperature range setting
The value is below the lower threshold
5.5 °C
10°F
at the area you
1
.
5

Publicidad

Tabla de contenido
loading

Tabla de contenido