Installation Information - Alecto SA-210 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

INSTALLATION INFORMATION:

Attach the ceiling plate using the included plugs and screws to the ceiling on a
location of choice. Wall mounting is not recommended for smoke detection. Pull
the yellow plate out of the ceiling side of the unit. Then put the detector to the
ceiling plate and, twist clockwise to lock it in place. Perform a first test by holding
the test key for two seconds. Also see the paragraph: "Testing".
USING, TESTING AND MAINTENANCE:
Using:
The smoke detector works if the yellow plate has been removed and the SA-210
has been mounted to the ceiling. The LED underneath the test button will now
flash ± every 42 seconds. Once smoke is detected, the alarm will sound. Once
the smoke disappears, the smoke alarm will stop automatically
Hush function
The Hush function allows the user to decrease the smoke detectors sensitivity
during an alarm. By pressing the "HUSH/TEST" button the smoke detector is de-
creased for a period of 9 minutes. The red led flashes 1x every 9 seconds in Hush
mode. After 19 minutes the smoke detector resets to its default sensitivity. For
example, this can be used when the smoke detector gives alarm during cooking.
Time-out function:
The time-out function allows you to preventively lower the sensitivity of the smoke
detector. By pressing the "HUSH/TEST" button without an active alarm, you
reduce the smoke detectors sensitivity for 9 minutes. The LED lights up 1x every 9
seconds during Hush mode.
After 9 minutes the smoke detector resets to its default sensitivity. You can use
this mode for example when you know that a situation (for example: cooking) will
product smoke and there is no danger.
Test:
By pressing the "HUSH/TEST" button 1x, the alarm of the SA-210 will be checked.
Keep the "HUSH/TEST" pressed for a minimum of 5 seconds. If you immediately
hear 3 audio tones, the alarm is in excelent working condition. Check the alarm
every week. In alarm status the device generates 85dB(A) sound. Do not test the
device using candles, open fire, cigarettes etc.
ATTENTION:
If the cause of an alarm is unclear, assume it's caused by fire. Immediately
evacuate the building.
Keep the smoke detectors out of range of children.
Protect against dust during rennovations. Without protection the smoke
detectors will lose their functionality.

Publicidad

Tabla de contenido
loading

Tabla de contenido