Descargar Imprimir esta página

Bpt XA/300LR US R4 Manual Del Usuario página 2

Ocultar thumbs Ver también para XA/300LR US R4:

Publicidad

Idiomas disponibles

Idiomas disponibles

RESIDENTIAL INSTALLATION WITH X2 BLOCKS
X2 Block - 2
X2 Block X2 - 1
Master
XA/300LR
ICB/300
XAV/300
HPV/1+
HAV/200+
HIA/300+
ICP/LR+
...HEP/306+
...HTS
Master and Slave entry panels:
HEV/301, HEC/301, HET/301, AZV/304, AZ/304.
2
X2 block
entry
panels
Master
X2 block
entry
panels
Slave
Slave
Slave
IPD/300LR
Porter
switchboard
300 entry panels
HPV/1+
HAV/200+
HIA/300+
1
2
3
4
5
6
HAC/300LR+
7
8
9
0
C
2HTS
P
S
T
block-type installation, program all
entry panels first.
If there is an IPD/300LR porter
switchboard
and
accessories, they will be program-
med automatically on exiting pro-
gramming.
1 - PROGRAMMING
RECEIVERS
1.1 - Enter
receiver
programming
mode (yellow LED flashes).
1.2 - Lift the handset of the receiver to
be programmed.
1.3 - Press the two receiver buttons
and
at the same time for at least
1 s;
the unit communicates with the system
300 entry panel or porter (default set-
ting entry panel n. 1).
1.4 - Make the relevant call from the
entry panel or IPD/300LR, if fitted;
the receiver sounds to confirm the pro-
gramming.
1.5 - Repeat the operations in points
1.2, 1.3 and 1.4 for all the receivers.
1.6 - Exit programming mode.
NOTA. You can change the default
entry panel used to program the
users by selecting any of the system
300 entry panels or the IPD/300LR
switchboard, if there is one (see
chapter
5-ALTERING
USER PROGRAMMING DEVICE).
If you decide to program receivers
from X2 blocks, follow the instruc-
tions provided with the X2 entry
panel.
2 - PROGRAMMING
SYSTEM 300 ENTRY PANELS,
MASTER X2
BLOCK ENTRY PANELS
Besides determining the entry panel
scanning order, programming lets you
set the type of system 300 entry panel
(with or without a surveillance camera),
duration of the solenoid door lock
command (the latter is only for system
300 pushbutton panels), and the num-
ber of X2 blocks in the system.
Proceed as follows:
2.1 - Enter entry panel programming
mode (yellow LED on).
System 300 entry panels
(ICP/LR or HAC/300LR) (fig. 3)
The line engaged indicator light (if pre-
sent) lights up on pushbutton panels,
whilst the SETUP MODE message is
displayed on digital entry panels.
2.2 - Programming entry panel and
door lock release time.
• Programming entry panel with sur-
veillance camera and door lock release
time 1 s.
- Press call button n.1.
Wait for audible confirmation: two
notes.
• Programming entry panel with no
surveillance camera and door lock
release time 1s.
- Press call button n.1.
Wait for audible confirmation: two
notes.
- Press call button n.1 again.
Wait for audible confirmation: one
note.
NOTE. If you wish to alter the door
lock release operating time from 1 s
to 4 s, 8 s or 16 s, carry out the above
operations in point 2.2 or 2.3 using
3
call buttons n. 2, 3 and 4 respectively.
2.3 - Repeat the procedure in 2.2 for
the remaining entry panels (in the order
in which the entry panels are to be
IOD/303LR
scanned).
Once the procedure is finished, the
engaged indicator light goes off or the
SETUP MODE message disappears to
indicate that programming is complete.
Master X2 block entry panels
(HEV/301, HEC/301, AZV/304, etc.)
(fig. 3)
WARNING. X2 block entry panels
can only be programmed with ver-
sion 3.0 units or later versions.
2.4 - To set each Master X2 block
entry panel, two procedures are
necessary, given below.
A - Identification of block entry
panel.
B - Setting of number of user calls
in the block.
A - Identification
of block entry panel
1 - Remove and replace jumper
SW2 (receiver programming mode)
on the first Master entry panel
only (the one connected to the
XA/300LR power supplier, fig. 3)
belonging to the first X2 block and
await confirmation;
DEFAULT
confirmed by double audible signal
and the solenoid door lock release
command being activated.
B - Definition of number
of user calls in the block
This programming is performed,
again from the Master entry panel,
proceeding as follows:
1 - Set number of buttons used on
audio/video panel (0, 1, 2, 3 or 4):
- press the last button used on the
audio/video panel (fig.4); if there isn't
one, press the first button on the addi-
tional panel (fig.4).
Audio/video panel
(max 4 buttons)
HEV/301
HET/301
HEC/301
AZV/304
AZ/304
2 - Set total number of user calls in the
block:
- press the last call button used.
2.5 - Repeat the procedure in point
2.4 for the following first Master
entry panels belonging to the other
blocks.
Programming of other Slave entry
panels belonging to the same block
(fig. 3) must be performed afterwards
(see "Programming X2 Slave entry
panels" section).
2.6 - Exit programming mode.
Sample settings of number
of user calls
EXAMPLE 1 - X2
Targha audio-only entry panel with 3
calls, with no additional pushbutton
panels (fig. 5).
Additional
panel
HEP/306
HEP/312D
VZS/308C
or digital
HAC/300LR
4
block
featuring

Publicidad

loading