INSTALLATION

Installing/Replacing the lamp

For the installation, you need one of the following lamps:
PHILIPS CDM-T 150W/830 G12
OSRAM HQI-T150/NDL PRO 6000h 230/150W G12
Topspot HIT 230V/150W G-12 6000h nw
GE CMH 150/T G12 6000h
OMNILUX OMD 230V/150W G12 6000h 4200K
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp or check the operating hour meter (if available) regularly and replace the lamp in
time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
All manuals and user guides at all-guides.com

DANGER TO LIFE!

Only install the lamp with the device switched off!
Unplug from mains before!
No. 91014045
No. 91201794
No. 91201797
No. 91201800
No. 91201805
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
19/49
(8) Power supply
(9) Fuseholder
(10) Housing screws
(11) DIP-switches
(12) Control LED
(13) DMX-Out socket
(14) DMX-In socket
(15) Lamp system