Weathermatic SmartLine SL800 Guia De Inicio Rapido

Publicidad

Enlaces rápidos

®
Programming
Panel (See
owner's manual)
NEXT
NEXT
PGM
PGM
BACK
BACK
Hinged Wiring
Compartment
Door
Fuse
FUSE STATUS LIGHT
GREEN: GOOD FUSE
RED: BLOWN FUSE
NO LIGHT: NO POWER
24V Auxiliary
Power Connections
Hot Post
Sensor Connections
Common Wire Connection
Master Valve/Pump Connection
Controller Installation
The SL800 is designed for indoor installations only. Choose a location that is
convenient to valve wiring and a 120V (230V for export models E-SL800
and E-SL800A) outlet. The SL800 is not intended for operation by children
and should be installed in a location convenient for operation by adults but
out of the reach of children. Choose a location with good lighting to
maximize display readability.
Installing Optional SLHUB
(If you are not installing an SLW Weather Station, you can skip this step.)
• If you are going to use an SLW Weather Station with the SL800, the first
step in installation is to open and discard the SLHUB compartment cover
on the back of the SL800 housing. Insert the SLHUB (packaged with the
SLW) with the green communication cable terminal to the lower left.
Carefully push the SLHUB onto the 10- pin connector. Use provided screw
to secure SLHUB to SL800 cabinet. Connect the RED, BLACK and SILVER
wires to the SLHUB matching color polarity as shown on the terminal.
Secure the communication cable in the restraint provided on the housing.
Mounting the SL800 Controller
• Install a wall anchor. Insert the provided mounting screw into the the wall
anchor to a depth allowing the head of the screw to be inserted in the
keyhole at the top center of the housing. The housing should be flat against
the wall with the head of the screw in the keyhole.
• Remove the hinged wiring compartment door and set it aside temporarily.
• Level the controller housing on the wall and secure it with a second screw
through the center housing standoff located just below the terminal position
for Zone 1. If additional screws are desired, use the left and right standoffs
at the bottom of the housing.
24V Valve Wiring
• Connect Common Valve Wire to COM screw.
• Connect optional master valve or pump start to MV-P terminal and the
Common terminal.
• Connect zones 1 through 4 to terminal screws provided. Note: You should
always locate zones by using the Hot Post connection. On the SL800, you
may use the left 24V auxiliary terminal position as a Hot Post. This terminal
position is protected by the fuse.
• If you require constant 24VAC power for a wireless sensor or other
optional powered equipment, use the two 24VAC auxiliary terminals
provided at the left end of the terminal strip.
RUN MANUAL PROGRAM
RUN MANUAL PROGRAM
SUN
MON
TUE WED
THU
FRI SAT
PGM
A
B
ADJUST VALUE
ADJUST VALUE
C
D
FAULT
NO AC
ZONE START
AUTO
AUTO
ADJUST
ADJUST
MODE
MODE
STANDARD
STANDARD
ACTIVE
ACTIVE
SENSOR
SENSOR
BYPASS
BYPASS
LA LUZ ESTADO FUSIBLE
VERDE: FUSIBLE BUENO
ROJO: FUSIBLE MALO
NO LUZ: NO ELECTRICIDAD
S1
S2 COM MV/P
2
3
4
5
6
7
Conduit
Connections
Skirt for
for expansion
24V AC
modules (SLM2)
Wiring
Terminals for zones 1 through 4
SL800 Controller Installation Instructions
Wall mounting keyhole
24V AC Connection
24V AC Cable
Restraints
Additional wall mounting
SLHUB
screw locations (optional).
Compartment
24V AC Power Wiring
• Insert male connector into female receptacle on the side of the SL800
housing. Use provided restraints to route the power cable down the side of
the housing. Plug transformer into convenient outlet.
Adding Extra Zones
• Connections for two SLM2 modules are provided at the right side of the
terminal strip to expand the SL800 to 6 or 8 zones. The SLM2 modules are
hot swappable and the SL800 will instantly recognize the additional
zones. Push each module onto the male connector. Use the provided
terminal screws to secure the front of the module. Do not skip module
position 5 and 6. Always install that module position first. To remove an
SLM2 module, first remove the terminal screws and then use a small flat
blade screwdriver to move the module forward from the rear connector.
Connecting a Sensor
• Use the S1 and S2 positions on the terminal strip for connecting a
standard type rain sense or freeze sense. Discard the wire loop if a sensor
is connected. Important: The wire loop must be left in place if a sensor is
not in use. Do NOT use the S1 and S2 for connecting a Weathermatic
SLW. See SLHUB instructions above.
Conduit Skirt
• Complete your installation by sliding the conduit skirt into the locking slots
on the housing. If you have installed an SLW, route the communication
cable through any of the side openings provided on the skirt. Use two
additional provided screws to secure the bottom of the skirt to the wall.
• Replace the hinged wiring compartment door.
Electrical Data for the SL800.
• The SL800 uses a 750mA transformer to power a total of 2 valves
including a master valve or pump start relay. Take caution when installing
a pump relay that maximum output current does not exceed 720mA.
• The SL800 does not use a backup battery. All programming information
including time and date are non-volatile.
• Replacement fuse for the SL800 is a 1.0A, 3AG, slow blow fuse.
Restraint for SLW
communication cable
®

Publicidad

loading

Resumen de contenidos para Weathermatic SmartLine SL800

  • Página 1 Important: The wire loop must be left in place if a sensor is Carefully push the SLHUB onto the 10- pin connector. Use provided screw not in use. Do NOT use the S1 and S2 for connecting a Weathermatic to secure SLHUB to SL800 cabinet. Connect the RED, BLACK and SILVER SLW.
  • Página 2 SL800 Controller Quick Start Guide ® Auto Adjust Programming RUN MANUAL PROGRAM RUN MANUAL PROGRAM AUTO AUTO ADJUST ADJUST MODE MODE STANDARD STANDARD NEXT NEXT Installation of optional SLW weather TUE WED FRI SAT ACTIVE ACTIVE station and Standard Programming is ADJUST VALUE ADJUST VALUE SENSOR...