Descargar Imprimir esta página

Elevated Draining; Emptying Solution Tank; Other Cleaning Uses With Machine; Blower Hose Cleaning - Nobles QUICK CLEAN 1500 Manual De Operador

Ocultar thumbs Ver también para QUICK CLEAN 1500:

Publicidad

Idiomas disponibles

Idiomas disponibles

ELEVATED DRAINING

Use the convenient pump--out procedure if drain site
exceeds 13 inches / 33 cm in height.
1. Attach gray blower hose to blower hose connector
and to vacuum hose connector (Figure 29).
FIG. 29
ATTENTION: Make sure recovery tank lid is secure
before activating blower.
2. Remove drain hose knob, direct hose into
elevated drain site and activate blower (Figure 30).
FIG. 30

EMPTYING SOLUTION TANK

1. Connect black recovery hose at front of machine
and remove solution tank lid.
2. Press vacuum/blower switch towards vacuum
symbol.
3. Extract remaining rinse solution from solution tank
and flush tank with clean water (Figure 31).
Quick Clean 1500 (06- -06)
Home
Find... Go To..
FIG. 31
4. Turn off machine, unplug power cord and drain
recovery tank.

OTHER CLEANING USES WITH MACHINE

BLOWER HOSE CLEANING

Use gray blower hose to blow out debris from hard to
reach areas and to remove dust and cobwebs from
overhead fixtures and vents (Figure 32).
ATTENTION: Do not use machine for dry pick- -up.
FIG. 32

CARPET CLEANING (OPTION)

Machine can be used to clean carpet with the use of
an optional carpet cleaning floor tool (See OPTIONS).
1. Connect fill--hose (supplied with machine) to water
faucet and fill tank with 15 gallons / 57 L of hot
water, 140° F / 60° C maximum temperature.
DO NOT ADD CLEANING AGENTS TO
SOLUTION TANK, certain cleaning agents may
damage pump. Use a pump--up sprayer to apply
the cleaning agent mix to the carpet.
OPERATION
15

Publicidad

loading

Productos relacionados para Nobles QUICK CLEAN 1500