Grounded tools must be plugged into an outlet properly
installed and grounded in accordance with all codes
and ordinances. Never remove the grounding prong or
modify the plug in any way. Do not use any adaptor
plugs. Check with a qualified electrician if you are in
doubt as to whether the outlet is properly grounded.
If the tools should electrically malfunction or break down,
grounding provides a low resistance path to carry electricity
away from the user. Improper grounding can shock, burn or
electrocute. Grounded tools are equipped with three
conductor cord and three prong type plugs. Before plugging
in the tool be certain the outlet voltage supplied is within the
voltage marked on the nameplate. Do not use "AC only"
rated tools with a DC power supply.
Replace damaged cords immediately.
!
WARNING
Use of damaged cords can shock, burn
or electrocute.
Always use proper extension cord. If an
!
WARNING
extension cord is necessary, a cord
with adequate size conductors should be used to
prevent excessive voltage drop, loss of power or over-
heating. The table shows the correct size to use, de-
pending on cord length and nameplate amperage
rating of tool. If in doubt, use the next heavier gauge.
Always use U.L. and CSA listed extension cords.
NOTE: The smaller the gauge number, the heavier the cord.
X-Bench Accessory Control Box
Accessory Control Box
Only use the accessory control box for power tools designed
for use with accessory insert plates and suggested power
tools in this manual.
It is intended to be the mains switch for benchtop
applications if your Skil power tool is used in the insert plate.
It is also intended as a convenience outlet for use with your
Skil Circular Saw and Miter Saw.
FOR CONTINUATION OF ENGLISH SEE PAGE 11
All manuals and user guides at all-guides.com
Grounded Tools
Extension Cords
"SAVE THESE INSTRUCTIONS!"
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Tool's
Ampere
Cord Length in Feet
Rating
25
50 100 150
18
16
16
3-6
18
16
14
6-8
18
16
14
8-10
16
16
14
10-12
14
12
—
12-16
Accessory Switch
The accessory control box has an accessory On/Off switch
with lock off key. Be aware of your position while using the X-
Bench for fast emergency shut off power. Remove lock off
key to disable switch when not in use.
4.
2
Wire Sizes in mm
Cord Length in Meters
15 30
60 120
14
.75 .75 1.5 2.5
12
.75 1.0 2.5 4.0
12
.75 1.0 2.5 4.0
12
1.0 2.5 4.0
—
—
— —
—
—