Advance planning
Before you begin
9 WARNING
Improper installation of gas appliances and ventilation
hoods can create a risk for carbon monoxide which can be
harmful. To reduce the risk of carbon monoxide poisoning,
ensure the gas appliance is properly installed according to
the manufacturer's instructions, as well as ensuring the
hood is vented to the outside for proper exhausting of
gases or fumes.
Gas cooking appliances release carbon monoxide that can
be harmful or fatal if inhaled. To reduce the risk of fire and
to properly exhaust air, the exhaust gases extracted by the
hood should be vented outside of the building only.
Consult local building codes for requirements or
restrictions related to installation of ventilation products in
recirculation mode.
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the
appliance's installation manual or combination matrix.
NOTICE: The hood can be damaged from excessive heat
if a range or rangetop is operated with multiple burners at
high settings under a hood that is installed at minimum
clearances and is turned off.
Distance from cooking surface
The installation height above a cooktop, rangetop or
range is recommended as a minimum height of 30''
(762 mm); however, it is necessary to follow the cooking
appliance manufacturer's installation instructions for
proper hood height.
Refer to local building codes for the latest requirements or
restrictions when installing ventilation products in
recirculation mode.
Parts included
•
Metal transition with backdraft damper
•
Stainless steel baffle filters
•
Stainless steel grease trays
•
Stainless steel filter spacers
•
Side trims
•
Blower adapter
•
Fastener assortment*
4
* Hardware provided is for mounting through standard
thickness drywall or plaster into wood studs. Installers are
responsible to provide hardware for other types of
mounting situations.
Tools and parts needed
•
Blower (refer to the Ventilation Planning Guide for
compatible blowers)
•
Ducting as needed (refer to "Equivalent duct lengths
for commonly used transitions" table)
•
Aluminum tape (DO NOT use duct tape.)
•
1/2'' (13 mm) conduit if required (follow local codes)
•
1'' (25.4 mm) Strain relief
•
Cross-head screwdriver
•
T-20 star-head screwdriver
•
11/32'' nut driver or socket and ratchet
•
Drill with 3/16'' (4.76 mm) drill bit
•
Framing material (as necessary for framework)
•
Circular saw or jigsaw
•
Wire stripper
•
Tape measure
•
Protective work gloves
IMPORTANT: DO NOT throw away any packaging until
appliance is fully installed.
Optional accessories available for separate purchase
Refer to www.thermador.com for more details.
Accessories
EXTNCB25W
25 ft. remote and in-line blower
extension cable
EXTNSET4
25 ft. remote and in-line blower
extension cable adapter kit
RFPLT600P
Roof plate for use with remote
blower VTR1FZ
RFPLT1000P
For use with remote blower
VTR2FZ
REMCPW
Remote control panel
Description