Synchronising
the lamps
1. Program each lamp individually
with the desired flash sequence as
described in the "Programming mode"
instructions. (We recommend selecting
the same flash sequence for all lamps
that are to be synchronised.)
2. Connect the lamps as specified in
the circuit diagram. Here, all green
lines are connected to each other.
11

Function test

Mandatory for all
emergency vehicles
(police,
fire service etc. )
+
All manuals and user guides at all-guides.com
2XD 010 311-201
2XD 010 311-001
2XD 010 311-101
The function test indicates that the
lamps are operating correctly. In the
event of a defective LED or any other
malfunctions, the control lamp will be
extinguished.
+
white
brown
green
+
30
31
...
...
31
yellow