Unoccupied. This mode aims to short periods of absence. Avoids the temperature to
surpass the established limit temperature for cooling and heating mode, generating
demand with a set-point temperature previously established by the installer (27˚ C / 81˚ F
in cooling mode and 17.5˚ C / 63˚ F in heating mode by default) for returning to the
EN
allowed values, as long as the zone is on.
When interacting with the zone while this mode is selected, the controller displays the
unoccupied override warning. If the set-point temperature is changed, it is maintained for
EN
the pre-established period of time (60 minutes by default) and returns to the set-point
temperature of the unoccupied mode.
FR
Vacation. This mode aims to long periods of absence. It turns off all the zones to save
energy and turns them on avoiding the temperature to surpass the established limit
temperature (35˚ C / 95˚ F in cooling mode and 10˚ C / 50˚ F in heating mode), generating
IT
demand with the previous set-point temperature before activating the vacation mode.
When interacting with the zone while this mode is selected, the controller displays the
vacation override warning. If the set-point temperature is changed, it is maintained for
PT
the pre-established period of time (60 minutes by default) and turns off the zones again.
Stop. The air-conditioning system will remain switched off regardless of the demand
DE
status of any zone, all the motorized dampers will remain opened.
Time Schedules
Access the time schedules menu by pressing the time schedule icon. To create a new schedule
press "Add Schedule". After creating the time schedule, select the schedule type to perform,
the days of the week, the start time of the schedule and the zones involved. Press save to
complete the time schedule creation process.
Once the schedule has been created, press on it to modify or remove it.
System Settings
Press on the icon to access the parameters.
Name. Allows to change the name of the system.
Heating stages. This parameter is used to set the heating stage in the zone. These are the
features to be configured:
−
Air. It activates the heating air in the zone.
−
Radiant. It activates radiant heating.
−
Air+Radiant. It activates both air and radiant heating in the zone and allows the
user to select the desired heating stage.
10