OPERATION SRP-02
Pressing shortly the programmed push-button in local mode (<2 sec.) or roller blind
switch (optional) causes the roller blind moves. Another short pressing of the same
push-button or the switch causes the roller blind stops at a required level. Pressing
the push-button or the switch longer (>2 sec.) causes comfort mode activates (the
roller blind moves in a required direction and stops according to the adjusted time).
Pressing shortly transmitter's push-button (programmed in the central mode) causes
complete opening or closing of the roller blind.
RADIO TRANSMITTERS PROGRAMMING
LOCAL mode:
1. Press PROG push-button of SRP-02 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button.
2. Press and release transmitter's first push-button (movement ). LED red diode
switches on (first signal pulsates, next the signal is constant).
3. Press and release the second transmitter's push-button (movement ). LED red
diode switches on (signal pulsates) and then switches off - THE TRANSMITTER IS
ADDED.
CENTRAL mode:
1. Press PROG push-button of SRP-02 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button. Wait (for about
5 seconds) till LED red diode switches on (first signal pulsates, next the signal is
constant).
2. Press and release transmitter's first push-button (movement ). LED red diode
switches on (first signal pulsates, next the signal is constant).
3. Press and release the second transmitter's push-button (movement ). LED red
diode switches on (the signal pulsates) and next it switches off - THE TRANSMITTER
IS ADDED.
An exemplary programming procedure with P-257/4 remote control. The procedure for
the rest of radio EXTA FREE transmitters is analogous with reservation that 2-channel
transmitters can be programmed only in one mode - local or central.
CAUTION: If push-button changes are required for local and central control (in a
4-channel transmitter) the programming procedure should be for two modes sepa-
rately (first local control push-buttons, then central control push-buttons). In case
of a 2- channel transmitter the change from local control to central control should
start with controller's memory deletion and only then transmitter's programming
procedure for central mode can start. One transmitter can be added during one
programming cycle. Full memory is signalled with pulsating LED red diode.