5
ELECTRICAL INSTALLATION
5.2
Pin assignment of the connections
5.3
Connecting the supply voltage
6
Commissioning
6.1
Sensing range setting
12
Overview of pin assignment
Table 1: Pin assignment
WTT4SLC
-3X32xxAxx
1
2
3
4
NOTICE
Risk of damage to the device!
The device can become damaged if it is connected to a voltage supply that is already
switched on.
Only connect the device when the supply cable is de-energized.
•
The device must be connected to a power supply unit with the following properties:
•
Supply voltage DC 10.8 V – 28.8 V (SELV/PELV as per currently valid standards)
Electricity source with at least 3 W power
•
To ensure protection against short-circuits/overload in the customer's supply cables,
the wire cross-sections used must be appropriately selected and protected.
Q1
Sensing range setting
-3X22xxAxx
+ (L+)
MF
- (M)
Q
/C
1
4
3
1
2
white background (90%)
Example:
Sensing range on black, 6%,
x = 800 mm, y = 60 mm
-3X11xxAxx
1 = brn
2 = wht
3 = blu
4 = blk
0.14 mm
2
AWG26
x
y
8022570 | SICK