Description of the appliance
1. Light switch
2. Motor speed switch
3. Work light
4. Suction grid with grease filter
Standard accessories included:
Screws:
Duct with no return valve
Plug for unused outlet hole
Function
The hood may be used as follows:
- For air exhausting
- For air recycling
Exhausting
The appliance has two exhaust outlets; D and E
(Fig. 2).
Connect the hood to the smoke exhaust hose by
using the connecting ring G with no return valve
(bayonet coupling).
Insert plug H in the unused exhaust hole (bayonet
coupling).
Plug H is for closing the unused hole.
Attention! In the horizontal runs the duct must be
slightly slanted (about 10°) and directed upwards
to vent the air easily from the room to the outside.
The hood cannot be connected
to flues f other appliances that
run on energy sources other
than electricity.
Recycling
The air is filtered through a carbon filter and
recirculated into the room through the front grid
(fig. 3).
This version is used when there is no exhaust
duct for venting outdoors or when it is impossible
to install one.
1
EFT 604
1
EFT 600-2
Fig. 1
Fig. 2
Fig. 3
2
2
4
3
31