KOBAN
Reach setting (sensitivity)
Reach is the term used to describe the radii of the more or less circular detection zone
produced on the ground after mounting the sensor light at a height of 2.5m, switch to the
on is "1", switch to the off is "0";The corresponding file of switch location and detection
distance
SENS:S1,S2
NOTE: The above detection distance is measured using a person who is between
1.6m~1.7m tall with an average build, moving at a speed of 1.0~1.5m/sec. if any of
these variables are changed, the detection distance will also resultantly change.
Time setting
Time can be set 10s to 30min.Any movement detected before this time elapse will re-start
the timer. It is recommended to select the shortest time for adjusting the detection zone
and for performing the walk test. Switch to the on is "1", switch to the off is "0"; the
corresponding file of switch location and detection distance as follow:
S3
3
TIME:S3,S4,S5
NOTE: after the light switches OFF, it takes approx. 1sec before it is able to start detecting
movement again. The light will only switch on in response to movement once this period
has elapsed.
Light-control setting
The chosen light response threshold can be infinitely from approx. 10lux-500lux. switch
to the on is "1", switch to the off is "0"; he corresponding file of switch location and
detection distance as follow:
S6
6
LUX:S6,S7,S8
Troubleshooting
Malfunction
The load will not work
The load work always
The load work without any
identifiable movement
as follow:
S2
S1
ON
1
2
S4
S5
4
5
S7 S8
7
8
wrong light-control setting selected
load faulty
mains switch OFF
continuous movement in the detection zone
the sensor not mounted for detecting
movement reliably
S1 S2 distance S1 S2 distance
0
0
2m
1
0
1
5m
1
S3 S4 S5 time
S3 S4 S5 time
0
0
0
10S
1
0
0
1
1min
1
0
1
0
5min
1
0
1
1
10min 1
S6 S7 S8 LUX
S6 S7 S8 LUX
0
0
0
24H
1
0
0
1
10 LUX
1
0
1
0
20 LUX
1
0
1
1
50 LUX
1
Cause
KDP TRIAC 01
Presence detector
0
8m
1
10m
0
0
15min
0
1
20min
1
0
25min
1
1
30min
0
0
100 LUX
0
1
200 LUX
1
0
300 LUX
1
1
500 LUX
Remedy
Adjust setting
Change load
Switch ON
check zone setting
securely mount enclosure
2