Operating Instructions

Technical specifications
Device:
VDS approval:
Range of application:
Audible alarm:
Power supply:
Battery life:
Ambient temperature:
Protection class:
Choosing the installation site
Installation sites for smoke detectors are regula-
ted in the binding application standard DIN EN
14676, which is applicable in Germany.
1. To provide comprehensive protection smoke
detectors should be installed in all rooms,
corridors, storage areas and basements. It may
be necessary to install more than one smoke
detector per area, especially in corridors longer
than 15 m. We recommend using several smoke
detectors for rooms larger than 60 m
ridors longer than 10 m.
2. You should at least provide minimum protection
and install a smoke detector in every bedroom
and children's room, as well as in corridors used
as emergency routes.
14
RM L 3100
RM L 3100
DIN EN 14604/VDS +
Q label/G216044
according to DIN 14676
85dB (at a distance of
3 m)
integrated 3V DC
lithium battery
10 years
0 ºC to 39 ºC
IP 20
2
and cor-